Search results
Results from the WOW.Com Content Network
Schematic representation of a normal sinus rhythm EKG wave. In electrocardiography, the PR interval is the period, measured in milliseconds, that extends from the beginning of the P wave (the onset of atrial depolarization) until the beginning of the QRS complex (the onset of ventricular depolarization); it is normally between 120 and 200 ms in duration.
Electrocardiography is the process of producing an electrocardiogram (ECG or EKG [a]), a recording of the heart's electrical activity through repeated cardiac cycles. [4] It is an electrogram of the heart which is a graph of voltage versus time of the electrical activity of the heart [ 5 ] using electrodes placed on the skin.
Wiggers diagram with mechanical (echo), electrical (ECG), and aortic pressure (catheter) waveforms, together with an in-ear dynamic pressure waveform measured using a novel infrasonic hemodynography technology, for a patient with severe aortic stenosis.
The QRS complex is the combination of three of the graphical deflections seen on a typical electrocardiogram (ECG or EKG). It is usually the central and most visually obvious part of the tracing. It corresponds to the depolarization of the right and left ventricles of the heart and contraction of the large ventricular muscles.
The electrical axis of the heart is the net direction in which the wave of depolarization travels. It is measured using an electrocardiogram (ECG). Normally, this begins at the sinoatrial node (SA node); from here the wave of depolarisation travels down to the apex of the heart. The hexaxial reference system can be used to visualise the ...
Schematic representation of normal ECG In electrocardiography , the ST segment connects the QRS complex and the T wave and has a duration of 0.005 to 0.150 sec (5 to 150 ms). It starts at the J point (junction between the QRS complex and ST segment) and ends at the beginning of the T wave.
Exceptions to this include complete heart block and certain ventricular artificial pacemaker rhythms, where the P waves may be completely normal in shape, but ventricular depolarization bears no relation to them; in these cases, the speed of the "sinus rhythm of the atria" and the speed of the ventricular rhythm must be calculated separately. [2]
The hexaxial reference system is a diagram that is used to determine the heart's electrical axis in the frontal plane.. In electrocardiography, left axis deviation (LAD) is a condition wherein the mean electrical axis of ventricular contraction of the heart lies in a frontal plane direction between −30° and −90°.