A shunt is a device that is designed to provide a low-resistance path for an electrical current in a circuit. It is typically used to divert current away from a system or component in order to prevent overcurrent. Electrical shunts are commonly used in a variety of applications including power distribution systems, electrical measurement ...
Shunt resistor. The common and simple approach to current sensing is the use of a shunt resistor. That the voltage drop across the shunt is proportional to its current flow, i.e. ohm's law, makes the low resistance current shunt a very popular choice for current measurement system with its low cost and high reliability.
These shunt components can be referenced to the primary or secondary side. For simplified transformer analysis, admittance from shunt elements can be neglected. When shunt components have non-negligible effects on system operation, the shunt admittance must be considered. In the diagram below, all shunt admittances are referred to the primary side.
Reactance is defined as the imaginary part of electrical impedance, and is analogous to but not generally equal to the negative reciprocal of the susceptance – that is their reciprocals are equal and opposite only in the special case where the real parts vanish (either zero resistance or zero conductance). In the special case of entirely zero ...
In accelerator physics, shunt impedance is a measure of the strength with which an eigenmode of a resonant radio frequency structure (e.g., in a microwave cavity) interacts with charged particles on a given straight line, typically along the axis of rotational symmetry.
Four-point measurement of resistance between voltage sense connections 2 and 3. Current is supplied via force connections 1 and 4. In electrical engineering, four-terminal sensing (4T sensing), 4-wire sensing, or 4-point probes method is an electrical impedance measuring technique that uses separate pairs of current-carrying and voltage-sensing electrodes to make more accurate measurements ...
Ohmmeters can be either connected in series or parallel based on requirements (whether resistance being measured is part of circuit or is a shunt resistance). Micro-ohmmeters (microhmmeter or micro ohmmeter) make measurements of low resistance. Megohmmeters (also a trademarked device Megger) measure large values of
In a DC shunt generator, the voltage induced across the armature, V a, is directly proportional to the flux acting across it, The flux in a DC generator is directly proportional to the field current, I f. The critical field resistance is defined as the maximum field circuit resistance (for a given speed) with which the shunt generator would ...