An orifice plate is called a calibrated orifice if it has been calibrated with an appropriate fluid flow and a traceable flow measurement device. Plates are commonly made with sharp-edged circular orifices and installed concentric with the pipe and with pressure tappings at one of three standard pairs of distances upstream and downstream of the ...
A restrictive flow orifice (RFO) is a type of orifice plate.They are used to limit the potential danger, damage, or wastage of an uncontrolled flow from, for example, a compressed gas cylinder [1] [2] They are generally not limiting the flow during normal operation but if a fault or failure occurs causing uncontrolled flow the orifice will present a restriction, limiting the flow.
For example, an orifice plate produces a pressure drop that is a function of the square of the volume rate of flow through the orifice. A vortex meter primary flow element produces a series of oscillations of pressure. Generally, the physical property generated by the primary flow element is more convenient to measure than the flow itself.
The flow of real gases through thin-plate orifices never becomes fully choked. The mass flow rate through the orifice continues to increase as the downstream pressure is lowered to a perfect vacuum, though the mass flow rate increases slowly as the downstream pressure is reduced below the critical pressure. [10]
An orifice is any opening, mouth, hole or vent, as in a pipe, a plate, or a body Body orifice, any opening in the body of a human or animal; Orifice plate, a restriction used to measure flow or to control pressure or flow, sometimes given specialised names: Calibrated orifice, used to control pressure or flow
The coefficient of contraction is defined as the ratio between the area of the jet at the vena contracta and the area of the orifice. C c = Area at vena contracta/Area of orifice. The typical value may be taken as 0.611 for a sharp orifice (concentric with the flow channel). [2] [3] The smaller the value, the greater the effect the vena ...
In all testing the common requirement was a fully developed flow profile entering the orifice plate. [8] Accurate standard compliant meter designs must therefore ensure that a swirl free, fully developed flow profile is impinging on the orifice plate. There are numerous methods available to accomplish this.
A thermal mass flow meter has a turndown ratio of 1000:1. An orifice plate meter has a practical turndown ratio of 3:1. A turbine meter has a turndown ratio of 10:1. Rotary positive displacement meters have a turndown ratio of between 10:1 and 80:1, depending on the manufacturer and the application.