Among TIA-607-B's list of metallic components in need of bonding are racks, enclosures, ladders, surge protectors, cable trays, routers, switches and patch panels. Following the bonding of telecom infrastructure components, the entire system must be bonded to the building's main ground, which is sometimes also referred to as a grounding ...
A ground connection that is missing or of inadequate capacity may not provide the protective functions as intended during a fault in the connected equipment. Extra connections between ground and circuit neutral may result in circulating current in the ground path, stray current introduced in the earth or in a structure, and stray voltage.
Strictly speaking, the terms grounding or earthing are meant to refer to an electrical connection to ground/earth. Bonding is the practice of intentionally electrically connecting metallic items not designed to carry electricity. This brings all the bonded items to the same electrical potential as a protection from electrical shock.
The "local" earth/ground electrode provides "system grounding" [13] at each building where it is installed. The "Grounded" current carrying conductor is the system "neutral". Australian and New Zealand standards use a modified protective multiple earthing (PME [ 14 ] ) system called multiple earthed neutral (MEN).
The ground potential at different outlets may differ by as much as 10 to 20 volts [4] due to voltage drops from these currents. The diagram shows leakage current from an appliance such as an electric motor A flowing through the building's ground system G to the neutral wire at the utility ground bonding point at the service panel.
Equipotential bonding involves electrically connecting metalwork so that it is at the same voltage everywhere. Exact rules for electrical installations vary by country, locality, or supplying power company. [2] Equipotential bonding is done from where the distribution wiring enters the building to incoming water and gas services.
A multipoint ground system is more complicated to install and maintain over the long term, and can be more expensive to install. Star topology systems can be converted to multipoint systems by installing new conductors between old existing ones. However, this should be done with care as it can inadvertently introduce noise onto signal lines during the conversion process. The noise can be ...
ANSI/TIA-568 is a technical standard for commercial building cabling for telecommunications products and services. The title of the standard is Commercial Building Telecommunications Cabling Standard and is published by the Telecommunications Industry Association (TIA), a body accredited by the American National Standards Institute (ANSI).