  1. Results from the WOW.Com Content Network
  2. Thermoplastic-sheathed cable - Wikipedia

    en.wikipedia.org/wiki/Thermoplastic-sheathed_cable

    The following are nominal current ratings for copper conductors; long runs may require thicker wires to minimize voltage drop. White: 14 AWG wire (2.08 mm 2) for 15-amp circuits Yellow: 12 AWG wire (3.31 mm 2) for 20-amp circuits Orange: 10 AWG wire (5.26 mm 2) for 30-amp circuits

  3. American wire gauge - Wikipedia

    en.wikipedia.org/wiki/American_wire_gauge

    Wire sized 1 AWG is referred to as "one gauge" or "No. 1" wire; similarly, thinner sizes are pronounced "x gauge" or "No. x" wire, where x is the positive-integer AWG number. Consecutive AWG wire sizes thicker than No. 1 wire are designated by the number of zeros: No. 0, often written 1/0 and referred to as "one aught" wire

  4. Electrical wiring - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring

    A wire or cable has a voltage (to neutral) rating and a maximum conductor surface temperature rating. The amount of current a cable or wire can safely carry depends on the installation conditions. The international standard wire sizes are given in the IEC 60228 standard of the International Electrotechnical Commission.

  5. Electrical wiring in North America - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring_in_North...

    In both those instances the white wire should be identified as being hot, usually with black tape inside junction boxes. The neutral wire is identified by gray or white insulated wire, perhaps using stripes or markings. With lamp cord wire the ribbed wire is the neutral, and the smooth wire is the hot. NEC 2008 400.22(f) allows surface marking ...

  6. Power cable - Wikipedia

    en.wikipedia.org/wiki/Power_cable

    Modern two or three-wire+ground PVC-insulated cable (e.g., NM-B), produced by such brands as Romex [citation needed] Aluminum wire was used in the 1960s and 1970s as a cheap replacement for copper and is still used today, but this is now considered [by whom?] unsafe, without proper installation, due to corrosion, softness and creeping of ...

  7. Wire gauge - Wikipedia

    en.wikipedia.org/wiki/Wire_gauge

    Each notch is stamped with a number, and the wire or sheet, which just fits a given notch, is stated to be of, say, No. 10, 11, 12, etc., of the wire gauge. The circular forms of wire gauge measurement devices are the most popular, and are generally 3 + 3 ⁄ 4 inches (95 mm) in diameter, with thirty-six notches; many have the decimal ...

  8. Ampacity - Wikipedia

    en.wikipedia.org/wiki/Ampacity

    A single insulated conductor in free air has 70 A rating. Ampacity rating is normally for continuous current, and short periods of overcurrent occur without harm in most cabling systems. Electrical code rules will give ratings for wiring where short-term loads are present, for example, in a hoisting motor.

  9. Category:Wire gauges - Wikipedia

    en.wikipedia.org/wiki/Category:Wire_gauges

    See also , a chart comparing all known wire gauges to each other. Pages in category "Wire gauges" The following 11 pages are in this category, out of 11 total.