For example, the command to set the trigger mode of an instrument to "normal" may be given as "TRIGger:MODe NORMal". Here, the word " NORMal " is used as the argument to the " TRIGger:MODe " command. When multiple arguments are provided, the arguments are written as a comma-separated list.
You are free: to share – to copy, distribute and transmit the work; to remix – to adapt the work; Under the following conditions: attribution – You must give appropriate credit, provide a link to the license, and indicate if changes were made. You may do so in any reasonable manner, but not in any way that suggests the licensor endorses ...
In addition to the basic instrument, most oscilloscopes are supplied with a probe. The probe connects to any input on the instrument and typically has a resistor of ten times the oscilloscope's input impedance. This results in a 0.1 (‑10×) attenuation factor; this helps to isolate the capacitive load presented by the probe cable from the ...
A passive oscilloscope probe with a switch in the probe handle that selects 1× or 10× attenuation To minimize loading, attenuator probes (e.g., 10× probes) are used. A typical probe uses a 9 megohm series resistor shunted by a low-value capacitor to make an RC compensated divider with the cable capacitance and scope input.
PicoScope for Microsoft Windows is the full-featured oscilloscope application, and was first released in 1992 by Pico Technology.PicoScope software enables real-time scope display with zooming and panning, and buffers captured waveforms on the PC to enable engineers to view previous measurements. [9]
In this case, a probe can be put into the tool holder and programmed with G-code or other methods to touch off the work-piece, telling the machine where everything now is. After the machine knows everything's location, offsets are adjusted to start the next operation after the probe has been removed from the tool holder.
If the device is being electrically stimulated, the signal is acquired by the mechanical probe and is displayed on an oscilloscope or SMU. The mechanical probe station is often used in the failure analysis of semiconductor devices. There are two types of mechanical probes: active and passive. Passive probes usually consist of a thin tungsten ...
The first step of computing an eye pattern is normally to obtain the waveform being analyzed in a quantized form. This may be done by measuring an actual electrical system with an oscilloscope of sufficient bandwidth, or by creating synthetic data with a circuit simulator in order to evaluate the signal integrity of a proposed design.