enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Volt-ampere - Wikipedia

    en.wikipedia.org/wiki/Volt-ampere

    The volt-ampere (SI symbol: VA, [1] sometimes V⋅A or V A) is the unit of measurement for apparent power in an electrical circuit.It is the product of the root mean square voltage (in volts) and the root mean square current (in amperes). [2]

  3. Voltage converter - Wikipedia

    en.wikipedia.org/wiki/Voltage_converter

    The output will usually be DC in the range 1.5–24 V. Power supplies that output either 100–120 V AC or 210–240 V AC are available; they are called inverters, due to the conversion from DC to AC rather than the voltage change. The output frequency and waveform of an inverter may not accurately replicate that supplied by mains electricity ...

  4. Per-unit system - Wikipedia

    en.wikipedia.org/wiki/Per-unit_system

    The base value should only be a magnitude, while the per-unit value is a phasor. The phase angles of complex power, voltage, current, impedance, etc., are not affected by the conversion to per unit values. The purpose of using a per-unit system is to simplify conversion between different transformers.

  5. Split-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Split-phase_electric_power

    The line to neutral voltage is half the line-to-line voltage. Lighting and small appliances may be connected between a line wire and the neutral. Higher-power appliances, such as cooking equipment, space heating, water heaters, clothes dryers, air conditioners and electric vehicle charging equipment, are connected to the two line conductors.

  6. Three-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Three-phase_electric_power

    Three-phase transformer with four-wire output for 208Y/120 volt service: one wire for neutral, others for A, B and C phases. Three-phase electric power (abbreviated 3ϕ [1]) is a common type of alternating current (AC) used in electricity generation, transmission, and distribution. [2]

  7. Rating plate - Wikipedia

    en.wikipedia.org/wiki/Rating_plate

    power rating is specified in terms of apparent power (KVA or MVA), since the exact power factor will be determined by the external factors; [5] power factor (PF) is the nominal power factor for other ratings; usually PF = 0.8; [5] insulation class (B, F, H) for the primary coil. Typical value is F, although older generators might use class B; [5]

  8. Orders of magnitude (current) - Wikipedia

    en.wikipedia.org/wiki/Orders_of_magnitude_(current)

    400 V low voltage secondary side distribution transformer with primary 12 kV; 200 kVA (up to 1000 kVA also common) [7] 10 3: 2 kA 10.5 kV secondary side from an electrical substation with primary 115 kV; 63 MVA [8] 9.3 kA 2.7V, Ultracapacitor short circuit current [9] 10 4: 25 kA Lorentz force can crusher pinch [10] 30 kA Typical lightning ...

  9. Power factor - Wikipedia

    en.wikipedia.org/wiki/Power_factor

    In electrical engineering, the power factor of an AC power system is defined as the ratio of the real power absorbed by the load to the apparent power flowing in the circuit. . Real power is the average of the instantaneous product of voltage and current and represents the capacity of the electricity for performing