The United States Environmental Protection Agency allows concentration of 9% volume in occupied spaces without mandated egress time, or up to 10.5% for a limited time. Most fire suppression systems are designed to provide concentration of 6.25-9%. The HFC-227ea fire suppression agent was the first non-ozone-depleting replacement for Halon 1301.
Clean agent FS 49 C2 is an environmentally engineered, human safe, fast acting Clean Agent fire extinguishing gas for gaseous fire suppression installed in a suited fire suppression system. The gas consists of tetrafluoroethane, pentafluoroethane and carbon dioxide. [1] FS 49 C2 maintains breathable concentrations of oxygen in the air.
Alternatively, the ignition-limiting threshold is determined by performing a proper ignition test described in BSI PAS 95:2011 Hypoxic air fire prevention systems specification. [4] Smoke detectors are installed in protected volumes because, similar to gas suppression systems, hypoxic air does not prevent smoldering and pyrolyzing processes.
Gaseous fire suppression, also called clean agent fire suppression, is the use of inert gases and chemical agents to extinguish a fire. These agents are governed by the National Fire Protection Association (NFPA) Standard for Clean Agent Fire Extinguishing Systems – NFPA 2001 in the US, with different standards and regulations elsewhere.
Engineered fire suppression systems are design specific and most commonly used for larger installations where the system is designed for a particular application. Examples include large marine and land vehicle applications, server rooms, public and private buildings, industrial paint lines, dip tanks and electrical switch rooms.
Fire control is the practice of reducing the heat output of a fire, reducing the area over which the fire exists, or suppressing or extinguishing the fire by depriving it of fuel, oxygen, or heat (see fire triangle). Fire prevention and control is the prevention, detection, and extinguishment of fires, including such secondary activities as ...
An Ansul fire suppression system in a hospital cafeteria Fire suppression systems are used to extinguish, control, or in some cases, entirely prevent fires from spreading or occurring. Fire suppression systems have an incredibly large variety of applications, and as such, there are many different types of suppression systems for different ...
An anecdotal report of a carbon dioxide fire extinguisher was published in Scientific American in 1887 which describes the case of a basement fire at a Louisville, Kentucky pharmacy which melted a lead pipe charge with CO 2 (called carbonic acid gas at the time) intended for a soda fountain which immediately extinguished the flames thus saving ...