  2. Air flow meter - Wikipedia

    en.wikipedia.org/wiki/Air_flow_meter

    An air flow meter is a device similar to an anemometer that measures air flow, i.e. how much air is flowing through a tube. It does not measure the volume of the air passing through the tube, it measures the mass of air flowing through the device per unit time, though Thus air flow meters are simply an application of mass flow meters for the ...

  3. Standard cubic feet per minute - Wikipedia

    en.wikipedia.org/wiki/Standard_cubic_feet_per_minute

    For example, a mass flow rate of 1,000 kg/h of air at 1 atmosphere of absolute pressure is 455 SCFM when defined at 32 °F (0 °C) but 481 SCFM when defined at 60 °F (16 °C). Due to the variability of the definition and the consequences of ambiguity, it is best engineering practice to state what standard conditions are used when communicating ...

  4. Duct leakage testing - Wikipedia

    en.wikipedia.org/wiki/Duct_leakage_testing

    Duct leakage test in the US. A duct leakage tester is a diagnostic tool designed to measure the airtightness of forced air heating, ventilating and air-conditioning (HVAC) ductwork. A duct leakage tester consists of a calibrated fan for measuring an air flow rate and a pressure sensing device to measure the pressure created by the fan flow.

  5. Actual cubic feet per minute - Wikipedia

    en.wikipedia.org/wiki/Actual_cubic_feet_per_minute

    Actual cubic feet per minute (ACFM) is a unit of volumetric flow. It is commonly used by manufacturers of blowers and compressors. [1] This is the actual gas delivery with reference to inlet conditions, whereas cubic foot per minute (CFM) is an unqualified term and should only be used in general and never accepted as a specific definition without explanation.

  6. Testing, adjusting, balancing - Wikipedia

    en.wikipedia.org/wiki/Testing,_adjusting,_balancing

    Balancing is the methodical regulation of system fluid flows (air or water) through the use of acceptable procedures to achieve the desired or specified design airflow or water flow. When beginning the balance of a system, you must locate the terminal with the least amount of flow in regards to the engineer's drawing.

  7. Air changes per hour - Wikipedia

    en.wikipedia.org/wiki/Air_changes_per_hour

    Air changes per hour, abbreviated ACPH or ACH, or air change rate is the number of times that the total air volume in a room or space is completely removed and replaced in an hour. If the air in the space is either uniform or perfectly mixed, air changes per hour is a measure of how many times the air within a defined space is replaced each hour.

  8. Airflow - Wikipedia

    en.wikipedia.org/wiki/Airflow

    Airflow, or air flow, is the movement of air. Air behaves in a fluid manner, meaning particles naturally flow from areas of higher pressure to those where the pressure is lower. Atmospheric air pressure is directly related to altitude , temperature , and composition.

  9. Air flow bench - Wikipedia

    en.wikipedia.org/wiki/Air_flow_bench

    An air flow bench is a device used for testing the internal aerodynamic qualities of an engine component and is related to the more familiar wind tunnel. It is used primarily for testing the intake and exhaust ports of cylinder heads of internal combustion engines .