Controls for the reclosers range from the original electromechanical systems to digital electronics with metering and SCADA functions. The ratings of reclosers run from 2.4–38 kV for load currents from 10–1200 A and fault currents from 1–16 kA. [7] [8] On a 3-phase circuit, a recloser is more beneficial than three separate fuse cutouts.
An HVDC converter station (or simply converter station) is a specialised type of substation which forms the terminal equipment for a high-voltage direct current (HVDC) transmission line. [1] It converts direct current to alternating current or the reverse. In addition to the converter, the station usually contains:
Substation integration refers to combining data from the IED's local to a substation so that there is a single point of contact in the substation for all of the I&C data. Power-system automation processes rely on data acquisition; power-system supervision and power-system control all working together in a coordinated automatic fashion.
While the recloser does in fact help to break up distribution circuits into smaller, more manageable pieces, many protection schemes involving circuit breakers in distribution substations also apply reclosing to some extent, thus not "blacking out" the circuit and requiring a crew go to the station and reset a lockout.
In 2011, Baldor was acquired by ABB Ltd of Switzerland in an all-cash deal of US$4.2 billion ($1.1 billion debt included). The company continued to operate as Baldor Electric Company A Member of the ABB Group. On March 1, 2018, Baldor Electric Company's name was dissolved into the ABB brand, becoming ABB across all of its locations.
Most IEDs have a communication port and built-in support for standard communication protocols (DNP3, IEC104 or IEC61850), so they can communicate directly with the SCADA system or a substation programmable logic controller. Alternatively, they can be connected to a substation RTU that acts as a gateway towards the SCADA server.
Get today's best rates on high-yield and traditional savings accounts to more quickly grow your everyday nest egg.
A 115 kV to 41.6/12.47 kV 5 MVA 60 Hz substation with circuit switcher, regulators, reclosers and control building at Warren, Minnesota. It shows elements of low-profile construction, with apparatus mounted on individual columns. A substation is a part of an electrical generation, transmission, and distribution system.