Leg as in "hot leg" refers to one of multiple hot conductors in an electrical system. The most common residential and small commercial service in Canada and the U.S., single split-phase, 240 V, features a neutral and two hot legs, 240 V to each other, and 120 V each to the neutral. The most common three-phase system will have three hot legs ...
Over the K&T era multiple wire types evolved. Early wiring was insulated with cotton cloth and soft rubber, while later wiring was much more robust. Although the actual wire covering may have degraded over the decades, the porcelain standoffs have a nearly unlimited lifespan and will keep any bare wires safely insulated.
This three-wire single-phase system is common in North America for residential and light commercial applications. Circuit breaker panels typically have two live (hot) wires, and a neutral, connected at one point to the grounded center tap of a local transformer. Usually, one of the live wires is black and the other one red; the neutral wire is ...
The first rubber-insulated cables for US building wiring were introduced in 1922 with US patent 1458803, Burley, Harry & Rooney, Henry, "Insulated electric wire", issued 1923-06-12, assigned to Boston Insulated Wire and Cable . These were two or more solid copper electrical wires with rubber insulation, plus woven cotton cloth over each ...
So if A–B, B–C and C–A are all 240 volts, then A–N and C–N will both be 120 volts, but B–N will be 208 volts. Other types of three-phase supplies are wye connections, ungrounded delta connections, or corner-grounded delta [2] (ghost leg configuration) connections. These connections do not supply split single-phase power, and do not ...
If heating equipment designed for a 240-volt system is connected to two phases of a 208-volt supply, it will produce only 75% of its rated heating effect. Single-phase motors may have taps to allow their use on either 208-volt or 240-volt supply.
This type of ballast is common in 220–240V countries (And in North America, up to 30W lamps). Ballasts are rated for the size of lamp and power frequency. In North America, the AC voltage is insufficient to start long fluorescent lamps, so the ballast is often a step-up autotransformer with substantial leakage inductance (to limit current flow).
Electric wiring. conduit - underground for line voltage, vulnerable locations, under or in constructed elements-pavements; cable, wire - underground per codes for line and low voltage, above ground at stake-mounted and tree mounted fixtures. Light fixtures - fixed location - line voltage (120 V U.S. or 240 V Europe) and low voltage (12 V U.S.) [2]