Search results
Results from the WOW.Com Content Network
At least one author takes a different approach in order to avoid a need for the expression freestream static pressure. Gracey has written "The static pressure is the atmospheric pressure at the flight level of the aircraft". [15] [16] Gracey then refers to the air pressure at any point close to the aircraft as the local static pressure.
In fluid dynamics, the pressure coefficient is a dimensionless number which describes the relative pressures throughout a flow field. The pressure coefficient is used in aerodynamics and hydrodynamics. Every point in a fluid flow field has its own unique pressure coefficient, C p.
The fan maintains a constant static pressure in the discharge duct regardless of the position of the VAV box. Therefore, as the box closes, the fan slows down or restricts the amount of air going into the supply duct. As the box opens, the fan speeds up and allows more air flow into the duct, maintaining a constant static pressure. [11]
A diffuser is "a device for reducing the velocity and increasing the static pressure of a fluid passing through a system”. [1] The fluid's static pressure rise as it passes through a duct is commonly referred to as pressure recovery. In contrast, a nozzle is used to increase the discharge velocity and lower the pressure of a fluid passing ...
Static pressure is identical to pressure and can be identified for every point in a fluid flow field. A point in a fluid flow where the flow has come to rest (that is to say, speed is equal to zero adjacent to some solid body immersed in the fluid flow) is of special significance. It is of such importance that it is given a special name—a ...
In heating, ventilation, and air conditioning (HVAC), testing, adjusting and balancing (TAB) are the three major steps used to achieve proper operation of heating, ventilation, and air conditioning systems. TAB usually refers to commercial building construction and the specialized contractors who employ personnel that perform this service.
Compressor characteristic is a mathematical curve that shows the behaviour of a fluid going through a dynamic compressor.It shows changes in fluid pressure, temperature, entropy, flow rate etc.) with the compressor operating at different speeds.
The airtightness of a building is often expressed in terms of the leakage airflow rate through the building's envelope at a given reference pressure (usually 50 pascal) [10] divided by the: Heated building volume V. At 50·Pa, it is called the air change rate at 50 Pa and usually noted n 50 (units: h −1). [13] [14] Envelope area A E.