Search results
Results from the WOW.Com Content Network
[citation needed] In a traditional grid dominated by synchronous generators, a strong grid with SCR greater than 3.0 will have the desired voltage stability and active power reserves. [4] A weak grid (with SCR values between 2.0 and 3.0 [6]) can exhibit voltage instability and control problems. [5] A grid with SCR below 2.0 is very weak. [6]
In a synchronous generator, [1] the short circuit ratio is the ratio of field current required to produce rated armature voltage at the open circuit to the field current required to produce the rated armature current at short circuit. [1] [2] This ratio can also be expressed as an inverse of the saturated [3] direct-axis synchronous reactance ...
Short circuit ratio (or SCR) has multiple meanings: Short circuit ratio (synchronous generator) , a value used to characterize the stability of an electromechanical generator Short circuit ratio (electrical grid) , a metric to characterize the grid strength ("stiffness").
The neutral current can be determined by adding the three phase currents together as complex numbers and then converting from rectangular to polar co-ordinates. If the three-phase root mean square (RMS) currents are I L 1 {\displaystyle I_{L1}} , I L 2 {\displaystyle I_{L2}} , and I L 3 {\displaystyle I_{L3}} , the neutral RMS current is:
Phase-fired control (PFC), also called phase cutting or phase-angle control, is a method for power limiting, applied to AC voltages. [1] It works by modulating a thyristor , SCR , triac , thyratron , or other such gated diode -like devices into and out of conduction at a predetermined phase angle of the applied waveform.
The load line shows how the collector load resistor (R L) constrains the circuit voltage and current. The diagram also plots the transistor's collector current I C versus collector voltage V CE for different values of base current I base. The intersections of the load line with the transistor characteristic curves represent the circuit ...
List of free analog and digital electronic circuit simulators, available for Windows, macOS, Linux, and comparing against UC Berkeley SPICE. The following table is split into two groups based on whether it has a graphical visual interface or not.
After reaching the rated current of the HV side, all three instruments reading (Voltmeter, Ammeter, and wattmeter readings) are recorded. The ammeter reading gives the primary equivalent of full load current I L. As the voltage applied for full load current in short circuit test on transformer is quite small compared to the rated primary ...