Most forms of uninterruptible power supply (UPS) can be either powered by battery or flywheel energy. These are ready for immediate use at the instant that the mains electricity fails, but the relatively small and finite amount of stored energy they contain makes them suitable for short periods of use, typically in the order of a few dozen minutes to a couple of hours depending on the actual load.
The run-time for a battery-operated UPS depends on the type and size of batteries and rate of discharge, and the efficiency of the inverter. The total capacity of a lead–acid battery is a function of the rate at which it is discharged, which is described as Peukert's law. Manufacturers supply run-time rating in minutes for packaged UPS systems.
Resistive/reactive load banks may be used for testing turbines, switchgear, rotary UPS, generators and UPS systems. They can also be used for integrated system testing of utility substation protection systems, particularly for more complex relays like distance, directional overcurrent, power directional and others.
is the actual time to discharge the battery (in hours). Using the above example, if a battery rated for 100 ampere-hours at a 20-hour rate has a Peukert constant of 1.2 and is discharged at a rate of 10 amperes, it would be fully discharged in time 20 ( 100 10 ⋅ 20 ) 1.2 {\displaystyle 20{\left({\frac {100}{10\cdot 20}}\right)^{1.2}}} , which ...
The Smart-UPS is a series of enterprise-level uninterruptible power supplies (UPS) made by American Power Conversion (APC). [1] Most of the units have a SmartSlot (with the exception of SC and SMC series) which accepts an optional interface card providing features ranging from network connectivity to temperature and humidity monitoring. [ 2 ]
A 12V VRLA battery, typically used in small uninterruptible power supplies and emergency lamps. A valve regulated lead–acid (VRLA) battery, commonly known as a sealed lead–acid (SLA) battery, [1] is a type of lead–acid battery characterized by a limited amount of electrolyte ("starved" electrolyte) absorbed in a plate separator or formed into a gel; proportioning of the negative and ...
A 200 kW Caterpillar diesel generator set in a sound attenuated enclosure used as an emergency backup at a sewage treatment substation in Atlanta, United States. A diesel generator (DG) (also known as a diesel GenSet) is the combination of a diesel engine with an electric generator (often an alternator ) to generate electrical energy . [ 1 ]
NASA G2 flywheel. Flywheel energy storage (FES) works by accelerating a rotor to a very high speed and maintaining the energy in the system as rotational energy.When energy is extracted from the system, the flywheel's rotational speed is reduced as a consequence of the principle of conservation of energy; adding energy to the system correspondingly results in an increase in the speed of the ...