For example, in power distribution networks, a large step-down transformer may have an off-load tap changer on the primary winding and an on load automatic tap changer on the secondary winding or windings. The high voltage tap is set to match long term system profile on the high voltage network (typically supply voltage averages) and is rarely ...
The 240 V secondary winding is center-tapped, and the center neutral wire is grounded, making the two end conductors "hot" concerning the center tap. These three wires run down the service drop to the building's electric meter and service panel. Connecting a load between the hot wire and the neutral gives 120 volts, which is used for lighting ...
For example, a transformer with a vector group of Dy1 has a delta-connected HV winding and a wye-connected LV winding. The phase angle of the LV winding lags the HV by 30 degrees. Note that the high-voltage (HV) side always comes before the low-voltage (LV) side, regardless of which is the primary winding.
An example of an application of an autotransformer is one style of traveler's voltage converter, that allows 230-volt devices to be used on 120-volt supply circuits, or the reverse. An autotransformer with multiple taps may be applied to adjust the voltage at the end of a long distribution circuit to correct for excess voltage drop; when ...
Both linear spacing and power-of-two-style Vernier spacing can be employed in establishing the tap positions, e.g., a four-tap transformer can provide taps at 0.25, 0.5, 0.75, 1.0 (linear) or 0.0625, 0.125, 0.25, and 0.5 (Vernier). (The limitations of the Vernier—in this case, that the maximum obtainable amplitude is 0.9375—are less ...
A tap-changer is an electrically operated (usually) mechanical device used for changing the tapping usually on the primary of a high voltage transmission transformer in order to alter the voltage at the transformer secondary for the purpose of regulation of the voltage at the load (consumer) end of the line.
Get AOL Mail for FREE! Manage your email like never before with travel, photo & document views. Personalize your inbox with themes & tabs. You've Got Mail!
Electromechanical regulators called voltage stabilizers or tap-changers, have also been used to regulate the voltage on AC power distribution lines. These regulators operate by using a servomechanism to select the appropriate tap on an autotransformer with multiple taps, or by moving the wiper on a continuously variable auto transfomer.