enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Cost of electricity by source - Wikipedia

    en.wikipedia.org/wiki/Cost_of_electricity_by_source

    The cost of a solar PV module make up the largest part of the total investment costs. As per the recent analysis of Solar Power Generation Costs in Japan 2021, module unit prices fell sharply. In 2018, the average price was close to 60,000 yen/kW, but by 2021 it is estimated at 30,000 yen/kW, so cost is reduced by almost half.

  3. Single-wire earth return - Wikipedia

    en.wikipedia.org/wiki/Single-wire_earth_return

    The secondary winding of the local transformer will supply the customer with either single ended single phase (N-0) or split-phase (N-0-N) power in the region's standard appliance voltages, with the 0 volt line connected to a safety earth that does not normally carry an operating current.

  4. List of railway electrification systems - Wikipedia

    en.wikipedia.org/wiki/List_of_railway...

    Except Wairarapa Line beyond Upper Hutt. Since 2011, the nominal voltage was 1600 V but with the same tolerances as 1500 V (i.e. 1300–1800 V), making it backwards-compatible with 1500 V rolling stock. Since May 2016 the operating voltage was increased to 1700 V DC following the full introduction of the Matangi EMUs. Philippines: Metro Manila

  5. Distribution transformer - Wikipedia

    en.wikipedia.org/wiki/Distribution_transformer

    A "transformer bank", widely used in North America: three single-phase transformers connected to make a 3-phase transformer. The low-voltage secondary windings are attached to three or four terminals on the transformer's side. In North American residences and small businesses, the secondary is often the split-phase 120/240-volt system. The 240 ...

  6. Split-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Split-phase_electric_power

    As shown in Fig. 1, either end to center has half the voltage of end-to-end. Fig. 2 illustrates the phasor diagram of the output voltages for a split-phase transformer. Since the two phasors do not define a unique direction of rotation for a revolving magnetic field , a split single-phase is not a two-phase system.

  7. High-leg delta - Wikipedia

    en.wikipedia.org/wiki/High-leg_delta

    Center-tapped delta transformer Center-tapped delta transformer voltages. High-leg delta service is supplied in one of two ways. One is by a three-phase transformer (or three single-phase transformers), having four wires coming out of the secondary, the three phases, plus a neutral connected as a center-tap on one of the windings.

  8. Pad-mounted transformer - Wikipedia

    en.wikipedia.org/wiki/Pad-mounted_transformer

    A single transformer may serve one large building or many homes. Pad-mounted transformers are made in power ratings from around 15 to around 5000 kVA and often include built-in fuses and switches. Primary power cables may be connected with elbow connectors, which can be operated when energized using a hot stick and allows for flexibility in ...

  9. 25 kV AC railway electrification - Wikipedia

    en.wikipedia.org/wiki/25_kV_AC_railway...

    The N700 Shinkansen uses a three-level converter to convert 25 kV single-phase AC to 1,520 V AC (via transformer) to 3 kV DC (via phase-controlled rectifier with thyristor) to a maximum 2,300 V three-phase AC (via a variable voltage, variable frequency inverter using IGBTs with pulse-width modulation) to run the motors.