enow.com Web Search

  1. Ads

    related to: 18 awg stranded copper wire 16 awg white w blue stripe

Search results

  1. Results from the WOW.Com Content Network
  2. American wire gauge - Wikipedia

    en.wikipedia.org/wiki/American_wire_gauge

    The resistance of copper wire is approximately ⁠ 1 ohms / 1000 feet ⁠ for 10 AWG, ⁠ 10 ohms / 1000 feet ⁠ for 20 AWG, ⁠ 100 ohms / 1000 feet ⁠ for 30 AWG, and so on. [ 5 ] : 27 Because aluminum wire has a conductivity of approximately 61% of copper, an aluminum wire has nearly the same resistance as a copper wire that is two sizes ...

  3. FASTON terminal - Wikipedia

    en.wikipedia.org/wiki/FASTON_terminal

    There are free-hanging wire and circuit board mounted versions of both tabs and receptacles. All widths come mostly in one of two tab thicknesses: 0.032 and 0.020 in (0.8 and 0.5 mm). All widths come mostly in one of two tab thicknesses: 0.032 and 0.020 in (0.8 and 0.5 mm).

  4. Wire gauge - Wikipedia

    en.wikipedia.org/wiki/Wire_gauge

    Wire gauges may be broadly divided into two groups, the empirical and the geometric. The first includes all the older gauge measurements, notably the Birmingham gauge (B.W.G. or Stubs) and the Lancashire. The origin of the B.W.G. is obscure. The numbers of wire were in common use earlier than 1735 when the measurements were officially defined. [1]

  5. Electrical wiring - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring

    For instance, instead of 14 AWG (American wire gauge) copper wire, aluminium wiring would need to be 12 AWG on a typical 15 ampere lighting circuit, though local building codes vary. Solid aluminium conductors were originally made in the 1960s from a utility-grade aluminium alloy that had undesirable properties for a building wire, and were ...

  6. 25-pair color code - Wikipedia

    en.wikipedia.org/wiki/25-pair_color_code

    The pattern then starts over with the first 25-pair group as white/blue, and continues indefinitely, in multiples of 600 pairs or parts thereof. For example, a 900-pair cable has the first 600 pairs in 24 groups of 25 pairs in a white binder, and the remaining 300 pairs in 12 groups of 25 pairs wrapped in a red binder.

  7. IEC 60228 - Wikipedia

    en.wikipedia.org/wiki/IEC_60228

    Comparison of SWG (red), AWG (blue) and IEC 60228 (black) wire gauge sizes from 0.03 to 200 mm² to scale on a 1 mm grid – in the SVG file, hover over a size to highlight it. In engineering applications, it is often most convenient to describe a wire in terms of its cross-section area, rather than its diameter, because the cross section is directly proportional to its strength and weight ...

  1. Ads

    related to: 18 awg stranded copper wire 16 awg white w blue stripe