  2. Heat detector - Wikipedia

    en.wikipedia.org/wiki/Heat_detector

    Rate-of-Rise (ROR) heat detectors operate on a rapid rise in element temperature of 6.7 to 8.3°C (12.1 to 14.9°F) increase per minute, irrespective of the starting temperature. This type of heat detector can operate at a lower temperature fire condition than would be possible if the threshold were fixed.

  3. EN 54 - Wikipedia

    en.wikipedia.org/wiki/EN_54

    The EN 54 series of standards covers the following topics and product groups related to fire detection and fire alarm systems: [6] [7] Introduction: the introduction to the series of standards contains a diagram of a fire alarm system as well as numerous definitions of terms that are used in the other parts of the series of standards.

  4. Template:NFPA 704 diamond - Wikipedia

    en.wikipedia.org/wiki/Template:NFPA_704_diamond

    Flammability 3: Liquids and solids that can be ignited under almost all ambient temperature conditions. Flash point between 23 and 38 °C (73 and 100 °F). E.g. gasoline code F: 4: Flammability 4: Will rapidly or completely vaporize at normal atmospheric pressure and temperature, or is readily dispersed in air and will burn readily.

  5. Fire alarm system - Wikipedia

    en.wikipedia.org/wiki/Fire_alarm_system

    A fire alarm control panel Fire alarm speaker and pull station. Fire alarm systems are composed of several distinct parts: Fire alarm control panel (FACP), or fire alarm control unit (FACU): This component, the hub of the system, monitors inputs and system integrity, controls outputs, and transmits information.

  6. Fire alarm control panel - Wikipedia

    en.wikipedia.org/wiki/Fire_alarm_control_panel

    A fire alarm control panel (FACP), fire alarm control unit (FACU), fire indicator panel (FIP), or simply fire alarm panel is the controlling component of a fire alarm system. The panel receives information from devices designed to detect and report fires, monitors their operational integrity, and provides for automatic control of equipment, and ...

  7. NFPA 72 - Wikipedia

    en.wikipedia.org/wiki/NFPA_72

    The NFPA 72 "covers the application, installation, location, performance, inspection, testing, and maintenance of fire alarm systems, supervising station alarm systems, public emergency alarm reporting systems, fire warning equipment and emergency communications systems (ECS), and their components."

  8. Control and indicating equipment - Wikipedia

    en.wikipedia.org/wiki/Control_and_Indicating...

    Control and indicating equipment is equipment for receiving, processing, controlling, indicating and initiating the onward transmission of information as used in fire alarm systems. The fire detection and fire alarm system subcommittee of ISO/TC 21, Equipment for Fire Protection and Fire Fighting, had oversight for development of five standards ...

  9. Adiabatic flame temperature - Wikipedia

    en.wikipedia.org/wiki/Adiabatic_flame_temperature

    The constant volume adiabatic flame temperature is the temperature that results from a complete combustion process that occurs without any work, heat transfer or changes in kinetic or potential energy. Its temperature is higher than in the constant pressure process because no energy is utilized to change the volume of the system (i.e., generate ...