enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Air changes per hour - Wikipedia

    en.wikipedia.org/wiki/Air_changes_per_hour

    Air changes per hour is a measurement intended to communicate the air change effectiveness of a space’s ventilation system. Discussion around the ASHRAE standard 62, Ventilation for Acceptable Indoor Air Quality led to the development of a more direct method of measuring air change effectiveness with the use of a tracer gas. [1]

  3. Passive ventilation - Wikipedia

    en.wikipedia.org/wiki/Passive_ventilation

    For standards relating to ventilation rates, in the United States refer to ASHRAE Standard 62.1-2010: Ventilation for Acceptable Indoor Air Quality. [16] These requirements are for "all spaces intended for human occupancy except those within single-family houses, multifamily structures of three stories or fewer above grade, vehicles, and aircraft."

  4. ASHRAE - Wikipedia

    en.wikipedia.org/wiki/ASHRAE

    ASHRAE was founded in 1894 at a meeting of engineers in New York City, formerly headquartered at 345 East 47th Street, and has held an annual meeting since 1895. [4] Until 1954 it was known as the American Society of Heating and Ventilating Engineers (ASHVE); in that year it changed its name to the American Society of Heating and Air-Conditioning Engineers (ASHAE). [5]

  5. Ventilation (architecture) - Wikipedia

    en.wikipedia.org/wiki/Ventilation_(architecture)

    In 1973, in response to the 1973 oil crisis and conservation concerns, ASHRAE Standards 62-73 and 62–81) reduced required ventilation from 10 CFM (4.76 L/s) per person to 5 CFM (2.37 L/s) per person. In cold, warm, humid, or dusty climates, it is preferable to minimize ventilation with outdoor air to conserve energy, cost, or filtration.

  6. Thermal destratification - Wikipedia

    en.wikipedia.org/wiki/Thermal_destratification

    Download as PDF; Printable version; In other projects ... air movement from destratification fans can be used to help meet ASHRAE Standard 62.1 by increasing the ...

  7. Indoor air quality - Wikipedia

    en.wikipedia.org/wiki/Indoor_air_quality

    In classrooms, the requirements in the ASHRAE standard 62.1, Ventilation for Acceptable Indoor Air Quality, would typically result in about 3 air changes per hour, depending on the occupant density. As the occupants are not the only source of pollutants, outdoor air ventilation may need to be higher when unusual or strong sources of pollution ...

  8. Heating, ventilation, and air conditioning - Wikipedia

    en.wikipedia.org/wiki/Heating,_ventilation,_and...

    ASHRAE regularly organizes two annual technical committees and publishes recognized standards for HVAC design, which are updated every four years. [56] Another popular society is AHRI, which provides regular information on new refrigeration technology, and publishes relevant standards and codes.

  9. Sick building syndrome - Wikipedia

    en.wikipedia.org/wiki/Sick_building_syndrome

    In 1973, in response to the oil crisis and conservation concerns, ASHRAE Standards 62-73 and 62-81 reduced required ventilation from 10 cubic feet per minute (4.7 L/s) per person to 5 cubic feet per minute (2.4 L/s) per person, but this was found to be a contributing factor to sick building syndrome. [18]