enow.com Web Search

  1. Ads

    related to: double bus breaker scheme

Search results

  1. Results from the WOW.Com Content Network
  2. Bus coupler - Wikipedia

    en.wikipedia.org/wiki/Bus_coupler

    A bus coupler is a device which is used to couple one bus to the other without any interruption in power supply and without creating hazardous arcs. A bus coupler is a breaker used to couple two busbars to perform maintenance on other circuit breakers associated with that busbar. It is achieved with the help of a circuit breaker and isolators.

  3. Substation - Wikipedia

    en.wikipedia.org/wiki/Substation

    The arrangement of switches, circuit breakers, and buses used affects the cost and reliability of the substation. For important substations a ring bus, double bus, or so-called "breaker and a half" setup can be used, so that the failure of any one circuit breaker does not interrupt power to other circuits, and so that parts of the substation ...

  4. Isolated-phase bus - Wikipedia

    en.wikipedia.org/wiki/Isolated-phase_bus

    In electrical engineering, isolated-phase bus (IPB), also known as phase-isolated bus (PIB) in some countries, is a method of construction for circuits carrying very large currents, typically between a generator and its step-up transformer in a steam or large hydroelectric power plant. Isolated phase bus during installation at the Bui Dam Ghana ...

  5. Single-line diagram - Wikipedia

    en.wikipedia.org/wiki/Single-line_diagram

    A typical one-line diagram with annotated power flows. Red boxes represent circuit breakers, grey lines represent three-phase bus and interconnecting conductors, the orange circle represents an electric generator, the green spiral is an inductor, and the three overlapping blue circles represent a double-wound transformer with a tertiary winding.

  6. Power system protection - Wikipedia

    en.wikipedia.org/wiki/Power_system_protection

    Zone definitions account for generators, buses, transformers, transmission and distribution lines, and motors. Additionally, zones possess the following features: zones overlap, overlap regions denote circuit breakers, and all circuit breakers in a given zone with a fault will open in order to isolate the fault.

  7. Ring main unit - Wikipedia

    en.wikipedia.org/wiki/Ring_main_unit

    It includes in one unit two switches that can connect the load to either or both main conductors, and a fusible switch or circuit breaker and switch that feed a distribution transformer. [1] The metal enclosed unit connects to the transformer either through a bus throat of standardized dimensions, or else through cables and is usually installed ...

  8. AOL

    search.aol.com

    The search engine that helps you find exactly what you're looking for. Find the most relevant information, video, images, and answers from all across the Web.

  9. Split-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Split-phase_electric_power

    Single-pole circuit breakers feed 120 V circuits from one of the 120 V buses within the panel, or two-pole circuit breakers feed 240-volt circuits from both buses. 120 V circuits are the most common, and used to power NEMA 1 and NEMA 5 outlets, and most residential and light commercial direct-wired lighting circuits.

  1. Ads

    related to: double bus breaker scheme