Diagram of a RAID 1 setup. RAID 1 consists of an exact copy (or mirror) of a set of data on two or more disks; a classic RAID 1 mirrored pair contains two disks.This configuration offers no parity, striping, or spanning of disk space across multiple disks, since the data is mirrored on all disks belonging to the array, and the array can only be as big as the smallest member disk.
RAID 6 requires a minimum of four disks. As with RAID 5, a single drive failure results in reduced performance of the entire array until the failed drive has been replaced. [11] With a RAID 6 array, using drives from multiple sources and manufacturers, it is possible to mitigate most of the problems associated with RAID 5.
RAID 01, also called RAID 0+1, is a RAID level using a mirror of stripes, achieving both replication and sharing of data between disks. [3] The usable capacity of a RAID 01 array is the same as in a RAID 1 array made of the same drives, in which one half of the drives is used to mirror the other half.
The CX series supports both SATA and Fibre Channel disks. Supported RAID levels are 1/0, 0, 1, 3, 5, and 6; the disks can be configured into groups with different RAID levels. Models of the CX series come in two configurations: Fibre Channel (transfer speeds max. 2 Gbit/s) and iSCSI (max. 1 Gbit/s). The exception is the CX700, which is FC only.
As of 2020, it includes a RAID system capable of RAID levels 0, 1, 5, and 10, a block level SSD caching accelerator ("Smart Response Technology") with support for write-back and write-through modes for speed or data protection of any disk or RAID array, and support for intelligent caching, speedy recovery from certain issues, and for PCI ...
For example, a RAID 1 array has about half the total capacity as a result of data mirroring, while a RAID 5 array with n drives loses 1/n of capacity (which equals to the capacity of a single drive) due to storing parity information. RAID subsystems are multiple drives that appear to be one drive or more drives to the user, but provide fault ...
Further, a RAID array may be a single SCSI device, but may contain many logical units, each of which is a "virtual" disk—a stripe set or mirror set constructed from portions of real disk drives. The SCSI ID, WWN, etc. in this case identifies the whole subsystem, and a second number, the logical unit number (LUN) identifies a disk device (real ...
There are five different RAID-Z modes: RAID-Z0 (similar to RAID 0, offers no redundancy), RAID-Z1 (similar to RAID 5, allows one disk to fail), RAID-Z2 (similar to RAID 6, allows two disks to fail), RAID-Z3 (a RAID 7 [a] configuration, allows three disks to fail), and mirror (similar to RAID 1, allows all but one of the disks to fail). [22]