ISO 11737 Sterilization of medical devices – Microbiological methods ISO 11737-1:2006 Part 1: Determination of a population of microorganisms on products; ISO 11737-2:2009 Part 2: Tests of sterility performed in the definition, validation and maintenance of a sterilization process; ISO/IEC 11756:1999 Information technology - Programming ...
The ISO 10993 set entails a series of standards for evaluating the biocompatibility of medical devices to manage biological risk. These documents were preceded by the Tripartite agreement and is a part of the international harmonisation of the safe use evaluation of medical devices. [1]
In microbiology, in the context of a sterilization procedure, the D-value or decimal reduction time (or decimal reduction dose) is the time (or dose of an antimicrobial drug) required, at a given condition (e.g. temperature) or set of conditions, to achieve a one-log reduction, that is, to kill 90% of relevant microorganisms. [1]
Ethylene oxide treatment is the most common chemical sterilization method, used for approximately 70% of total sterilizations, and for over 50% of all disposable medical devices. [ 26 ] [ 27 ] Ethylene oxide treatment is generally carried out between 30 and 60 °C (86 and 140 °F) with relative humidity above 30% and a gas concentration between ...
For example, medical device manufacturers design their sterilization processes for an extremely low SAL, such as 10 −6, which is a 1 in 1,000,000 chance of a non-sterile unit. SAL also describes the killing efficacy of a sterilization process. A very effective sterilization process has a very low SAL.
Validation is a requirement of food, drug and pharmaceutical regulating agencies such as the US FDA and their good manufacturing practices guidelines. Since a wide variety of procedures, processes, and activities need to be validated, the field of validation is divided into a number of subsections including the following:
Process performance qualification protocol is a component of process validation: process qualification. This step is vital in maintaining ongoing production quality by recording and having available for review essential conditions, controls, testing, and expected manufacturing outcome of a production process.
The SDSCS classifies sterilization techniques into three categories: critical, semi-critical, and non-critical. [11] For critical situations, or situations involving contact with sterile tissue or the vascular system, sterilize devices with sterilants that destroy all bacteria, rinse with sterile water, and use of chemical germicides.