Building codes in the U.S. specify ventilation rates as a minimum of 1 sq ft (0.093 m 2) of opening per 150 sq ft (14 m 2) (1:150) with a ratio of 1:300 in some conditions. [8] Warm air rises, so ceiling insulation is designed to have a higher r-value and the insulation is often installed between the ceiling joists or rafters.
For a given R-value, loose cellulose weighs roughly three times as much per square foot as loose fiberglass. [17] Ceiling structures should be inspected for signs of weakness before choosing a material for insulating the ceilings of existing structures. [18]
While open-cell foams typically have R-values of 3 to 4 per inch (RSI-0.53 to RSI-0.70 per inch), closed-cell foams can attain R-values of 5 to 8 per inch (RSI-0.88 to RSI-1.41 per inch). This is important if space is limited, because it allows a thinner layer of insulation to be used.
Fabric joints are often chosen to separate the duct segments because they usually cost 40% less than metal joints. Also metal joints place an additional loads onto duct segments. Metal joints prefer axial movements, and provide significant lateral loads onto duct segments. fabric joints cost $100 to $200 per square foot of joint (2010).
This is a list of insulation materials used around the world. Typical R-values are given for various materials and structures as approximations based on the average of available figures and are sorted by lowest value. R-value at 1 m gives R-values normalised to a 1 metre (3 ft 3 in) thickness and sorts by median value of the range.
The Energy Saving Ordinance (EnEV) 2013 clarified the requirement of thermal insulation of the ceiling. And it mentioned that if the ceiling was not fulfilled, thermal insulation will be needed in accessible ceilings over upper floor's heated rooms. [U-Value must be under 0.24 W/(m 2 ⋅K)] [31]