  2. Sterilization (microbiology) - Wikipedia

    en.wikipedia.org/wiki/Sterilization_(microbiology)

    Ethylene oxide treatment is the most common chemical sterilization method, used for approximately 70% of total sterilizations, and for over 50% of all disposable medical devices. [ 26 ] [ 27 ] Ethylene oxide treatment is generally carried out between 30 and 60 °C (86 and 140 °F) with relative humidity above 30% and a gas concentration between ...

  3. Central sterile services department - Wikipedia

    en.wikipedia.org/wiki/Central_sterile_services...

    Sterilization can also be achieved using ethylene oxide (ETO) gas. This process was created in the 1950s by the US military [4] and is used on items that cannot withstand the high temperatures of steam sterilization. ETO sterilization takes far longer than steam sterilization and is hazardous to workers, so alternative methods were created in ...

  4. Sterilant gas monitoring - Wikipedia

    en.wikipedia.org/wiki/Sterilant_Gas_Monitoring

    The odor threshold for these gases is above the PELs and for ethylene oxide it is 500 ppm, approaching that of the IDLH. [1] Odor is thus inadequate as a monitoring technique. Continuous gas monitors are used as part of an overall safety program to provide a prompt alert to nearby workers in the event that there is a leak of the sterilant gas ...

  5. ISO 10993 - Wikipedia

    en.wikipedia.org/wiki/ISO_10993

    Part 7: Ethylene oxide sterilization residuals Part 8: Selection of reference materials (withdrawn) Part 9: Framework for identification and quantification of potential degradation products Part 10: Tests for skin sensitization Part 11: Tests for systemic toxicity Part 12: Sample preparation and reference materials (available in English only)

  6. Moist heat sterilization - Wikipedia

    en.wikipedia.org/wiki/Moist_heat_sterilization

    Moist heat sterilization processes sterilize using hot air that is heavily laden with water vapor, which plays the most important role in the sterilization. [ 1 ] [ 2 ] Boiling a sample for 30 minutes or more will kill virtually all vegetative cells present, but will not kill spores , which can germinate shortly thereafter and resume growth.

  7. D-value (microbiology) - Wikipedia

    en.wikipedia.org/wiki/D-value_(microbiology)

    In microbiology, in the context of a sterilization procedure, the D-value or decimal reduction time (or decimal reduction dose) is the time (or dose of an antimicrobial drug) required, at a given condition (e.g. temperature) or set of conditions, to achieve a one-log reduction, that is, to kill 90% of relevant microorganisms. [1]

  8. Z-value (temperature) - Wikipedia

    en.wikipedia.org/wiki/Z-value_(temperature)

    "F 0" is defined as the number of equivalent minutes of steam sterilization at temperature 121.1 °C (250 °F) delivered to a container or unit of product calculated using a z-value of 10 °C. The term F-value or "F Tref/z " is defined as the equivalent number of minutes to a certain reference temperature (T ref ) for a certain control ...

  9. List of instruments used in microbiological sterilization and ...

    en.wikipedia.org/wiki/List_of_instruments_used...

    used in sterilization of heat-labile products like plastic or rubber syringes, catheters and gloves •X-ray source-do- •Infrared light source-do- •Ultraviolet light source-do- Inspissator: used to produce culture media for bacteriology that contain egg or serum, which coagulate on heating Tyndallizer