enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Attenuator (electronics) - Wikipedia

    en.wikipedia.org/wiki/Attenuator_(electronics)

    A 3 dB pad reduces power to one half, 6 dB to one fourth, 10 dB to one tenth, 20 dB to one hundredth, 30 dB to one thousandth and so on. When input and output impedances are the same, voltage attenuation will be the square root of power attenuation, so, for example, a 6 dB attenuator that reduces power to one fourth will reduce the voltage (and ...

  3. Attenuation - Wikipedia

    en.wikipedia.org/wiki/Attenuation

    In physics, attenuation (in some contexts, extinction) is the gradual loss of flux intensity through a medium. For instance, dark glasses attenuate sunlight, lead attenuates X-rays, and water and air attenuate both light and sound at variable attenuation rates. Hearing protectors help reduce acoustic flux from flowing into the ears.

  4. T pad - Wikipedia

    en.wikipedia.org/wiki/T_pad

    Figure 3. A T-pad attenuator formed from two symmetrical L sections. Because of the symmetry, R 1 = R 3 in this case. For an attenuator, Z and Y are simple resistors and γ becomes the image parameter attenuation (that is, the attenuation when terminated with the image impedances) in nepers. A T pad can be viewed as being two L sections back-to ...

  5. Cutoff frequency - Wikipedia

    en.wikipedia.org/wiki/Cutoff_frequency

    Most frequently this proportion is one half the passband power, also referred to as the 3 dB point since a fall of 3 dB corresponds approximately to half power. As a voltage ratio this is a fall to 1 / 2 ≈ 0.707 {\textstyle {\sqrt {1/2}}\ \approx \ 0.707} of the passband voltage. [ 1 ]

  6. Π pad - Wikipedia

    en.wikipedia.org/wiki/Π_pad

    Figure 3. A Π-pad attenuator formed from two symmetrical L sections. Because of the symmetry, R 1 = R 3 in this case. For an attenuator, Z and Y are simple resistors and γ becomes the image parameter attenuation (that is, the attenuation when terminated with the image impedances) in nepers. A Π pad can be viewed as being two L sections back ...

  7. Attenuation length - Wikipedia

    en.wikipedia.org/wiki/Attenuation_length

    In physics, the attenuation length or absorption length is the distance λ into a material when the probability has dropped to 1/e that a particle has not been absorbed. Alternatively, if there is a beam of particles incident on the material, the attenuation length is the distance where the intensity of the beam has dropped to 1/ e , or about ...

  8. Power dividers and directional couplers - Wikipedia

    en.wikipedia.org/wiki/Power_dividers_and...

    The term hybrid coupler originally applied to 3 dB coupled-line directional couplers, that is, directional couplers in which the two outputs are each half the input power. This synonymously meant a quadrature 3 dB coupler with outputs 90° out of phase. Now any matched 4-port with isolated arms and equal power division is called a hybrid or ...

  9. Noise temperature - Wikipedia

    en.wikipedia.org/wiki/Noise_temperature

    For instance, if stage 1 represents a 6 dB attenuator so that =, then = + +. Effectively the noise temperature of the amplifier T 2 {\displaystyle T_{2}} has been quadrupled, in addition to the (smaller) contribution due to the attenuator itself T 1 {\displaystyle T_{1}} (usually room temperature if the attenuator is composed of resistors ).