Search results
Results from the WOW.Com Content Network
Parfocal microscope objectives stay in focus when magnification is changed; i.e., if the microscope is switched from a lower power objective (e.g., 10×) to a higher power objective (e.g., 40×), the object stays in focus. Most modern bright-field microscopes are parfocal.
Antonie van Leeuwenhoek (1632–1723). The field of microscopy (optical microscopy) dates back to at least the 17th-century.Earlier microscopes, single lens magnifying glasses with limited magnification, date at least as far back as the wide spread use of lenses in eyeglasses in the 13th century [2] but more advanced compound microscopes first appeared in Europe around 1620 [3] [4] The ...
Bi-telecentric lens with 208 mm diameter front element and a C-mount camera interface 3D render simulating a photo taken with a fixed focal length and a telecentric lens. A telecentric lens is a special optical lens (often an objective lens or a camera lens) that has its entrance or exit pupil, or both, at infinity.
Two Leica oil immersion microscope objective lenses; left 100×, right 40×. The objective lens of a microscope is the one at the bottom near the sample. At its simplest, it is a very high-powered magnifying glass, with very short focal length. This is brought very close to the specimen being examined so that the light from the specimen comes ...
With no modification to the microscope, i.e. with a simple wide field light microscope, the quality of optical sectioning is governed by the same physics as the depth of field effect in photography. For a high numerical aperture lens, equivalent to a wide aperture, the depth of field is small (shallow focus) and gives good optical sectioning.
The optical microscope, also referred to as a light microscope, is a type of microscope that commonly uses visible light and a system of lenses to generate magnified images of small objects. Optical microscopes are the oldest design of microscope and were possibly invented in their present compound form in the 17th century.
The focus of the first lens is traditionally about 2mm away from the plane face coinciding with the sample plane. A pinhole cap can be used to align the optical axis of the condenser with that of the microscope. The Abbe condenser is still the basis for most modern light microscope condenser designs, even though its optical performance is poor.
The earliest reference to the use of conoscopy (i.e., observation in convergent light with a polarization microscope with a Bertrand lens) for evaluation of the optical properties of liquid crystalline phases (i.e., orientation of the optical axes) is in 1911 when it was used by Charles-Victor Mauguin to investigate the alignment of nematic and ...