enow.com Web Search

  1. Ads

    related to: condensate pump continuously running at 100% lower unit

Search results

  1. Results from the WOW.Com Content Network
  2. Cottam power stations - Wikipedia

    en.wikipedia.org/wiki/Cottam_power_stations

    The main extraction pump discharged the condensate to No.1 D.C. heater from which it cascaded down to No.2 and then to No.3 D.C. heater by gravity. Two lift pumps delivered the condensate to No.4 D.C. heater, from which it cascaded through No.5 D.C. heater to two deaerator lift pumps.

  3. Vapor-compression refrigeration - Wikipedia

    en.wikipedia.org/wiki/Vapor-compression...

    A representative pressure–volume diagram for a refrigeration cycle. Vapour-compression refrigeration or vapor-compression refrigeration system (VCRS), [1] in which the refrigerant undergoes phase changes, is one of the many refrigeration cycles and is the most widely used method for air conditioning of buildings and automobiles.

  4. Variable air volume - Wikipedia

    en.wikipedia.org/wiki/Variable_air_volume

    A VAV terminal unit, [9] often called a VAV box, is the zone-level flow control device. It is basically a calibrated air damper with an automatic actuator . The VAV terminal unit is connected to either a local or a central control system.

  5. Condensing boiler - Wikipedia

    en.wikipedia.org/wiki/Condensing_boiler

    Since the final exhaust from a condensing boiler has a lower temperature than the exhaust from an atmospheric boiler 38 °C (100 °F) vs. 204 °C (400 °F) a mechanical fan is always required to expel it, with the additional benefit of allowing the use of low-temperature exhaust piping (typically PVC in domestic applications) without insulation ...

  6. Steam–electric power station - Wikipedia

    en.wikipedia.org/wiki/Steam–electric_power_station

    The condensate pump then pumps the condensate water through a feedwater heater, which raises the temperature of the water by using extraction steam from various stages of the turbine. [5] [6] Preheating the feedwater reduces the irreversibilities involved in steam generation and therefore improves the thermodynamic efficiency of the system. [9]

  7. Condenser (heat transfer) - Wikipedia

    en.wikipedia.org/wiki/Condenser_(heat_transfer)

    The condensate drips down and collects at the bottom, often in a built-in pan called a hotwell. The shell side often operates at a vacuum or partial vacuum, produced by the difference in specific volume between the steam and condensate. Conversely, the vapor can be fed through the tubes with the coolant water or air flowing around the outside.

  8. Scroll compressor - Wikipedia

    en.wikipedia.org/wiki/Scroll_compressor

    A scroll compressor (also called spiral compressor, scroll pump and scroll vacuum pump) is a device for compressing air or refrigerant. [1] It is used in air conditioning equipment, as an automobile supercharger (where it is known as a scroll-type supercharger ) and as a vacuum pump .

  9. Flue-gas condensation - Wikipedia

    en.wikipedia.org/wiki/Flue-gas_condensation

    Flue gas condensation may cause the heat recovered to exceed the Lower Heating Value of the input fuel, and thus an efficiency greater than 100%. Since historically most combustion processes have not condensed the fuel, usual efficiency calculations assume the combustion products are not condensed.

  1. Ads

    related to: condensate pump continuously running at 100% lower unit