enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Flow coefficient - Wikipedia

    en.wikipedia.org/wiki/Flow_coefficient

    SG is the specific gravity of the fluid (for water = 1), ΔP is the pressure drop across the valve (expressed in psi). In more practical terms, the flow coefficient C v is the volume (in US gallons) of water at 60 °F (16 °C) that will flow per minute through a valve with a pressure drop of 1 psi (6.9 kPa) across the valve.

  3. Fixture unit - Wikipedia

    en.wikipedia.org/wiki/Fixture_unit

    The relationship between gallons per minute (gpm) and fixture unit is not constant, but varies with the number of fixture units. For example, 1000 FU is equivalent to 220 US gallons per minute (0.014 m 3 /s) while 2000 FU represents only 330 US gallons per minute (0.021 m 3 /s), about 1.5 times the flow rate.

  4. Water flow test - Wikipedia

    en.wikipedia.org/wiki/Water_flow_test

    where: [2] Q f = total residual flow during the test (gallons per minute); c = discharge coefficient (unitless). This is usually 1.0 if using a diffuser. If using a wand to measure the stagnation pressure, the coefficient value depends on the shape of the flow hydrant orifice.

  5. Hazen–Williams equation - Wikipedia

    en.wikipedia.org/wiki/Hazen–Williams_equation

    The equation for head loss in pipes, also referred to as slope, S, expressed in "feet per foot of length" vs. in 'psi per foot of length' as described above, with the inside pipe diameter, d, being entered in feet vs. inches, and the flow rate, Q, being entered in cubic feet per second, cfs, vs. gallons per minute, gpm, appears very similar.

  6. Miner's inch - Wikipedia

    en.wikipedia.org/wiki/Miner's_inch

    The miner's inch is a method of measuring the amount of flow a particular water supply system (such as a flume or sluice) is capable of supplying. The miner ’s inch measures the amount of water that would flow through a slot of a given area at a given pressure (for example, at a head of 6 inches of water , or 1.5 kPa .)

  7. What should you set your heat to in the winter? Avoid ... - AOL

    www.aol.com/set-heat-winter-avoid-thermostat...

    That means the cost for a professional to come to your home and inspect your unit (anywhere from $150 to $500, Consumer Reports estimates) can pay off in the long run. Consider investing in a ...

  8. 10 best Walmart Advent calendars that haven't sold out yet

    www.aol.com/lifestyle/best-advent-calendars-that...

    The 10 best holiday candles to make your home smell merry and bright. AOL. These are the only Amazon deals worth shopping this weekend: Somehow AirPods are at a new low. See all deals.

  9. Volumetric flow rate - Wikipedia

    en.wikipedia.org/wiki/Volumetric_flow_rate

    Volumetric flow rate should not be confused with volumetric flux, as defined by Darcy's law and represented by the symbol q, with units of m 3 /(m 2 ·s), that is, m·s −1. The integration of a flux over an area gives the volumetric flow rate. The SI unit is cubic metres per second (m 3 /s). Another unit used is standard cubic centimetres per ...