  2. Sweep frequency response analysis - Wikipedia

    en.wikipedia.org/wiki/Sweep_frequency_response...

    An initial SFRA test is carried out to obtain the signature of the transformer frequency response by injecting various discreet frequencies. This reference is then used for future comparisons. A change in winding position, degradation in the insulation, etc. will result in change in capacitance or inductance thereby affecting the measured curves.

  3. Short-circuit test - Wikipedia

    en.wikipedia.org/wiki/Short-circuit_test

    A different form of short-circuit testing is done to assess the mechanical strength of the transformer windings, and their ability to withstand the high forces produced if an energized transformer experiences a short-circuit fault. Currents during such events can be several times the normal rated current.

  4. Autotransformer - Wikipedia

    en.wikipedia.org/wiki/Autotransformer

    Other advantages of autotransformers include lower leakage reactance, lower losses, lower excitation current, and increased VA rating for a given size and mass. [ 2 ] An example of an application of an autotransformer is one style of traveler's voltage converter , that allows 230-volt devices to be used on 120-volt supply circuits, or the reverse.

  5. Per-unit system - Wikipedia

    en.wikipedia.org/wiki/Per-unit_system

    In the power systems analysis field of electrical engineering, a per-unit system is the expression of system quantities as fractions of a defined base unit quantity. . Calculations are simplified because quantities expressed as per-unit do not change when they are referred from one side of a transformer to t

  6. Volt-ampere - Wikipedia

    en.wikipedia.org/wiki/Volt-ampere

    VA ratings are also often used for transformers; maximum output current is then VA rating divided by nominal output voltage. [5] Transformers with the same sized core usually have the same VA rating. The convention of using the volt-ampere to distinguish apparent power from real power is allowed by the SI standard. [6] [page needed]

  7. Dynamic line rating for electric utilities - Wikipedia

    en.wikipedia.org/wiki/Dynamic_line_rating_for...

    They are based on "steady-state (equilibrium) ampacity" calculations. Emergency ratings are based on transient equations and models: they provide permissible overload ratings for a short and adjustable time (typically 5 to 30 minutes). Forecasting methods have been developed to determine intraday and day-ahead ampacity forecasts.

  8. AOL Mail

    mail.aol.com

    Get AOL Mail for FREE! Manage your email like never before with travel, photo & document views. Personalize your inbox with themes & tabs. You've Got Mail!

  9. Transformer utilization factor - Wikipedia

    en.wikipedia.org/wiki/Transformer_Utilization_factor

    The transformer utilization factor (TUF) of a rectifier circuit is defined as the ratio of the DC power available at the load resistor to the AC rating of the secondary coil of a transformer. [ 1 ] [ 2 ]