enow.com Web Search

  1. Ad

    related to: cfm from differential pressure calculator for gas furnace prices homeowners

Search results

  1. Results from the WOW.Com Content Network
  2. Actual cubic feet per minute - Wikipedia

    en.wikipedia.org/wiki/Actual_cubic_feet_per_minute

    Actual cubic feet per minute (ACFM) is a unit of volumetric flow. It is commonly used by manufacturers of blowers and compressors. [1] This is the actual gas delivery with reference to inlet conditions, whereas cubic foot per minute (CFM) is an unqualified term and should only be used in general and never accepted as a specific definition without explanation.

  3. Air changes per hour - Wikipedia

    en.wikipedia.org/wiki/Air_changes_per_hour

    It is measured by the number of air changes per hour (ACH) that occur when there is a differential pressure of 50 pascals between outside and inside the building. If an air volume equal to the inside volume of the building flows across the envelope in one hour, then ACH = 1. [ 11 ]

  4. Gas meter - Wikipedia

    en.wikipedia.org/wiki/Gas_meter

    An orifice gas meter consists of a straight length of pipe inside which a precisely known orifice plate creates a pressure drop, thereby affecting flow. Orifice meters are a type of differential meter, all of which infer the rate of gas flow by measuring the pressure difference across a deliberately designed and installed flow disturbance.

  5. Draft (boiler) - Wikipedia

    en.wikipedia.org/wiki/Draft_(boiler)

    In a water boiler, draft is the difference between atmospheric pressure and the pressure existing in the furnace or flue gas passage. [1] Draft can also be referred to as the difference in pressure in the combustion chamber area which results in the motion of the flue gases and the air flow.

  6. Flow measurement - Wikipedia

    en.wikipedia.org/wiki/Flow_measurement

    A Venturi meter constricts the flow in some fashion, and pressure sensors measure the differential pressure before and within the constriction. This method is widely used to measure flow rate in the transmission of gas through pipelines , and has been used since Roman Empire times.

  7. Pressure measurement - Wikipedia

    en.wikipedia.org/wiki/Pressure_measurement

    Differential pressure is the difference in pressure between two points. Differential pressure sensors are used to measure many properties, such as pressure drops across oil filters or air filters, fluid levels (by comparing the pressure above and below the liquid) or flow rates (by measuring the change in pressure across a restriction ...

  8. Standard cubic feet per minute - Wikipedia

    en.wikipedia.org/wiki/Standard_cubic_feet_per_minute

    When positive pressure is applied to a standard cubic foot of gas, it is compressed. When a vacuum is applied to a standard cubic foot of gas, it expands. The volume of gas after it is pressurized or rarefied is referred to as its "actual" volume. SCF and ACF for an ideal gas are related in accordance with the combined gas law: [2] [3]

  9. Infiltration (HVAC) - Wikipedia

    en.wikipedia.org/wiki/Infiltration_(HVAC)

    The infiltration rate is the volumetric flow rate of outside air into a building, typically in cubic feet per minute (CFM) or liters per second (LPS). The air exchange rate, (I), is the number of interior volume air changes that occur per hour, and has units of 1/h.

  1. Ad

    related to: cfm from differential pressure calculator for gas furnace prices homeowners