Search results
Results from the WOW.Com Content Network
Permanently installed electrical equipment, unless not required to, has permanently connected grounding conductors. Portable electrical devices with metal cases may have them connected to earth ground by a pin on the attachment plug (see AC power plugs and sockets). The size of power grounding conductors is usually regulated by local or ...
Insulated bushings can be installed either indoor, or outdoor, and the selection of insulation will be determined by the location of the installation and the electrical service duty on the bushing. For a bushing to work successfully over many years, the insulation must remain effective both in composition and design shape and will be key ...
A pothead is a type of insulated electrical terminal used for transitioning between overhead line and underground high-voltage cable or for connecting overhead wiring to equipment like transformers. [1] Its name comes from the process of potting or encapsulation of the conductors inside the terminal's insulating bushing.
Insulating supports are required at the points where they are supported by utility poles or transmission towers. Insulators are also required where wire enters buildings or electrical devices, such as transformers or circuit breakers, for insulation from the case. Often these are bushings, which are hollow insulators with the conductor inside them.
Sometimes the fittings are considered sufficiently conductive to bond (electrically unite) the metal conduit to a metal junction box (thus sharing the box's ground connection); other times, grounding bushings are used which have bonding jumpers from the bushing to a grounding screw on the box.
Bushing (bearing), a type of plain bearing; Bushing (electrical), an insulated device that allows a conductor to pass through a grounded conducting barrier; Bushing (isolator), a mechanical device used to reduce vibrational energy transfer between two parts; Drill bushing, a tool used to guide the placement of a hole when drilling in a workpiece
Hot is any line or neutral conductor (wire or otherwise) connected with an electrical system that has electric potential relative to electrical ground or line to neutral. Ground is a safety conductor with a low impedance path to earth. It is often called the "ground wire," or safety ground. It is either bare or has green insulation. [1]
Arcing horns protecting bushings on a distribution transformer. Arcing horns form a spark gap across the insulator with a lower breakdown voltage than the air path along the insulator surface, so an overvoltage will cause the air to break down and the arc to form between the arcing horns, diverting it away from the surface of the insulator. [3]