The EN 54 series of standards covers the following topics and product groups related to fire detection and fire alarm systems: [6] [7] Introduction: the introduction to the series of standards contains a diagram of a fire alarm system as well as numerous definitions of terms that are used in the other parts of the series of standards.
The NFPA 72 "covers the application, installation, location, performance, inspection, testing, and maintenance of fire alarm systems, supervising station alarm systems, public emergency alarm reporting systems, fire warning equipment and emergency communications systems (ECS), and their components."
The Underwriters Laboratories' UL 365 is a safety standard that governs the construction, performance, and maintenance of police station-connected burglar alarm units and systems. These systems are designed primarily for use in mercantile premises, including mercantile safes and vaults, as well as bank safes and vaults.
Mineral-insulated copper-clad cable is a variety of electrical cable made from copper conductors inside a copper sheath, insulated by inorganic magnesium oxide powder. The name is often abbreviated to MICC or MI cable, and colloquially known as pyro (because the original manufacturer and vendor for this product in the UK was a company called ...
The term "fire detection and fire alarm systems" is a fairly wide definition, including small systems whose field devices consist only of sounders and manual call points, to complex networked systems with a large number of automatic fire detectors, manual call points and sounders, connected to numerous networked control and indicating panels.
EN 54: Fire detection and fire alarm systems; EN 71: Safety of toys; EN 81: Safety of lifts; EN 115: Safety of escalators & Moving walks; EN 136: Respiratory protective devices - Full-face masks - Requirements, testing and marking; EN 166: Personal eye protection. Specifications; EN 196: Methods for testing cement (10 parts)
Plenum cable / ˈ p l ɛ n əm / is electrical cable that is laid in the plenum spaces of buildings. In the United States, plastics used in the construction of plenum cable are regulated under the National Fire Protection Association standard NFPA 90A: Standard for the Installation of Air Conditioning and Ventilating Systems.
Linear heat detection (LHD) (also known as linear detection wire or linear heat detection cable or linear heat) is a very commonly used method of fire detection. It can detect a fire anywhere along the length of the cable, and can be of lengths in excess of a kilometer. Applications can range from building fire alarm systems to mobile plant ...