Search results
Results from the WOW.Com Content Network
Wave intensity analysis is frequently used in the study of coronary artery hemodynamics where impedance analysis is seldom, if ever, used. [11] It played an important role in the development of the Instantaneous Wave-free Ratio as a measure of the functional effect of stenoses in the coronary arteries. This method informs an interventional ...
Applying spectral Doppler to the renal artery and selected interlobular arteries, peak systolic velocities, resistive index, and acceleration curves can be estimated (Figure 4) (e.g., peak systolic velocity of the renal artery above 180 cm/s is a predictor of renal artery stenosis of more than 60%, and a resistive index, which is a calculated ...
A Doppler ultrasound blood flow detector, commonly called Doppler wand or Doppler probe, and a sphygmomanometer (blood pressure cuff) are usually needed. The blood pressure cuff is inflated proximal to the artery in question. Measured by the Doppler wand, the inflation continues until the pulse in the artery ceases.
The arterial resistivity index (also called as Resistance index, abbreviated as RI), developed by Léandre Pourcelot , is a measure of pulsatile blood flow that reflects the resistance to blood flow caused by microvascular bed distal to the site of measurement.
Pulse wave velocity (PWV) is the velocity at which the blood pressure pulse propagates through the circulatory system, usually an artery or a combined length of arteries. [1] PWV is used clinically as a measure of arterial stiffness and can be readily measured non-invasively in humans, with measurement of carotid to femoral PWV (cfPWV) being ...
Pseudonormalisation shows a transmitral profile that appears normal. However, with the use of pulmonary vein pulsed wave Doppler, it can be shown that the relaxation pattern is abnormal (systolic blunting, a decrease in the height of the S wave). In addition, performance of a Valsalva manoeuvre will result in unmasking of the pseudonormal state.
The PAT signal is a form of pulse wave amplitude measured by incorporating both a unified pressure field and a specific isosbestic wavelength.Applying a uniform pressure field around the measured surface releases arterial wall motion restriction, magnifies the dynamic range of the recorded signal, and prevents the distention of the veins distal to the site of pressure application.
A JVP waveform. The jugular venous pulsation has a biphasic waveform. The a wave corresponds to right atrial contraction and ends synchronously with the carotid artery pulse. The peak of the 'a' wave demarcates the end of atrial systole. The x descent follows the 'a' wave and corresponds to atrial relaxation and rapid atrial filling due to low ...