Search results
Results from the WOW.Com Content Network
A Rankine cycle with two steam turbines and a single open feedwater heater. A feedwater heater is a power plant component used to pre-heat water delivered to a steam generating boiler. [1] [2] [3] Preheating the feedwater reduces the irreversibilities involved in steam generation and therefore improves the thermodynamic efficiency of the system ...
The feed water cycle begins with condensate water being pumped out of the condenser after traveling through the steam turbines. The condensate flow rate at full load in a 500 MW plant is about 6,000 US gallons per minute (400 L/s). Diagram of boiler feed water deaerator (with vertical, domed aeration section and horizontal water storage section).
List of gas-fired plants in Malaysia; Plant State Coordinates MW Type Owner/operator Refs Connaught Bridge Power Station: Selangor at Klang: 832: Combined cycle (1 ST, 2 GT), open cycle (4 GT) Tenaga Nasional Berhad: Genting Sanyen Kuala Langat Power Plant: Selangor at Kuala Langat
In this design, the inlet feedwater follows a continuous path without segmented sections for economizers, evaporators, and superheaters. This provides a high degree of flexibility as the sections are allowed to grow or contract based on the heat load being received from the gas turbine.
In thermal power plants, the purpose of a surface condenser is to condense the exhaust steam from a steam turbine to obtain maximum efficiency, and also to convert the turbine exhaust steam into pure water (referred to as steam condensate) so that it may be reused in the steam generator or boiler as boiler feed water.
Most central stations are fossil fuel power plants and nuclear power plants; some installations use geothermal steam, or use concentrated solar power (CSP) to create the steam. Steam turbines can also be used directly to drive large centrifugal pumps, such as feedwater pumps at a thermal power plant.
The greatest variation in the design of steam–electric power plants is due to the different fuel sources. Almost all coal, nuclear, geothermal, solar thermal electric power plants, waste incineration plants as well as many natural gas power plants are steam–electric. Natural gas is frequently combusted in gas turbines as well as boilers.
The economiser is a crucial component for efficient performance of a thermal power plant. It is a non-steaming type of heat exchanger which is placed in the convective zone of the furnace. It takes the heat energy of the flue gases for heating the feed water before it enters the boiler drum.