A calibration curve plot showing limit of detection (LOD), limit of quantification (LOQ), dynamic range, and limit of linearity (LOL).. In analytical chemistry, a calibration curve, also known as a standard curve, is a general method for determining the concentration of a substance in an unknown sample by comparing the unknown to a set of standard samples of known concentration. [1]
This standard curve is then used to determine the concentration of the unknown protein. The following elaborates on how one goes from the standard curve to the concentration of the unknown. First, add a line of best fit, or Linear regression and display the equation on the chart.
The Standard addition method, often used in analytical chemistry, quantifies the analyte present in an unknown. This method is useful for analyzing complex samples where a matrix effect interferes with the analyte signal. In comparison to the calibration curve method, the standard addition method has the advantage of the matrices of the unknown ...
These three equations show that the curves for CO 2 and HCO − 3 intersect at [H +] eq = K 1, and the curves for HCO − 3 and CO 2− 3 intersect at [H +] eq = K 2. Therefore, the values of K 1 and K 2 that were used to create a given Bjerrum plot can easily be found from that plot, by reading off the concentrations at these points of ...
Enzyme kinetics is the study of the rates of enzyme-catalysed chemical reactions. In enzyme kinetics, the reaction rate is measured and the effects of varying the conditions of the reaction are investigated. Studying an enzyme's kinetics in this way can reveal the catalytic mechanism of this enzyme, its role in metabolism, how its activity is ...
Equilibrium unfolding. In biochemistry, equilibrium unfolding is the process of unfolding a protein or RNA molecule by gradually changing its environment, such as by changing the temperature or pressure, pH, adding chemical denaturants, or applying force as with an atomic force microscope tip. [1][2] If the equilibrium was maintained at all ...
The calibration curve that does not use the internal standard method ignores the uncertainty between measurements. The coefficient of determination (R 2 ) for this plot is 0.9985. In the calibration curve that uses the internal standard, the y-axis is the ratio of the nickel signal to the yttrium signal.
Standard solutions are commonly used to determine the concentration of an analyte species via calibration curve. A calibration curve is obtained by measuring a series of standard solutions with known concentrations, which can be used to determine the concentration of an unknown sample using linear regression analysis. [4]