Search results
Results from the WOW.Com Content Network
60947-4-3 AC-55b Switching incandescent lamps 60947-4-3 AC-56a Switching transformers 60947-4-3 AC-56b Switching of capacitor batteries 60947-4-3 AC-58a Control of a hermetically sealed refrigeration compressor motor with automatic reset of overload releases: 8-hour operation with starting currents for starting, maneuvering, operation 60947-4-2
3–5 times rated current I n, e.g. a nominally 10 A device will trip at 30–50 A C 5–10 times I n: D 10–14 times I n: K 8–12 times I n. For the protection of loads that cause frequent short-duration (approximately 400 ms to 2 s) current peaks in normal operation Z 2–3 times I n for durations on the order of tens of seconds.
In both those instances the white wire should be identified as being hot, usually with black tape inside junction boxes. The neutral wire is identified by gray or white insulated wire, perhaps using stripes or markings. With lamp cord wire the ribbed wire is the neutral, and the smooth wire is the hot. NEC 2008 400.22(f) allows surface marking ...
A three-wire three-phase circuit is usually more economical than an equivalent two-wire single-phase circuit at the same line-to-ground voltage because it uses less conductor material to transmit a given amount of electrical power. [3] Three-phase power is mainly used directly to power large induction motors, other electric motors and other ...
IEC 60724 Short-circuit temperature limits of electric cables with rated voltages of 1 kV (U m = 1,2 kV) and 3 kV (U m = 3,6 kV) IEC TR 60725 Consideration of reference impedances and public supply network impedances for use in determining the disturbance characteristics of electrical equipment having a rated current ≤75 A per phase
Dominator 1 was modified from a 2007 Chevrolet Tahoe that was used during the 2008 storm chasing season and debuted in the 2009 chase season. The modifications included adding bulletproof sheet metal and transparent Lexan armor to protect against flying debris near tornadoes, and an external roll cage and racing-style safety harnesses in case of a vehicle roll. [3]
A residual-current device (RCD), residual-current circuit breaker (RCCB) or ground fault circuit interrupter (GFCI) [a] is an electrical safety device, more specifically a form of Earth-leakage circuit breaker, that interrupts an electrical circuit when the current passing through line and neutral conductors of a circuit is not equal (the term residual relating to the imbalance), therefore ...
A distribution board (also known as panelboard, circuit breaker panel, breaker panel, electric panel, fuse box or DB box) is a component of an electricity supply system that divides an electrical power feed into subsidiary circuits while providing a protective fuse or circuit breaker for each circuit in a common enclosure.