Comparison of SWG (red), AWG (blue) and IEC 60228 (black) wire gauge sizes from 0.03 to 200 mm² to scale on a 1 mm grid – in the SVG file, hover over a size to highlight it. In engineering applications, it is often most convenient to describe a wire in terms of its cross-section area, rather than its diameter, because the cross section is directly proportional to its strength and weight ...
The table below shows various data including both the resistance of the various wire gauges and the allowable current based on a copper conductor with plastic insulation. The diameter information in the table applies to solid wires. Stranded wires are calculated by calculating the equivalent cross sectional copper area. Fusing current (melting ...
IEC metric screw sized connectors is a family of electrical connectors defined by IEC that are named according to their ISO metric screw thread, namely M5, M8 and M12. [1] The number gives their outer screw thread diameter in millimeters as with the identically named screws.
Also, larger aluminum stranded building wire made with AA-8000 series alloy of aluminum is used for electrical services (e.g. service entrance conductors from the utility connection to the service breaker panel) and for larger branch circuits such as for sub-panels, ranges, clothes dryers and air-conditioning units.
For example, NM 14-2 cable contains three conductors (two plus one ground) at 14 gauge, a size typically used for circuits protected at 15 amperes. Circuits with larger currents (such as for electric furnaces, water heaters, air conditioners, or sub-mains to additional circuit panels) will have larger conductors.
A table of the gauge numbers and wire diameters is shown below. [1] [2] The basis of the system is the thou (or mil in US English), or 0.001 in. Sizes are specified as wire diameters, stated in thou and tenths of a thou (mils and tenths). The wire diameter diminishes with increasing size number.
Each diameter was multiplied by 0.890526 to give the next lower size. This is now the American wire gauge (AWG), and is prevalent in North America and used to some extent in over 65 countries, with a market share of about 30% of all power and control wires and cables.
Below is a list of NEMA enclosure types; these types are further defined in NEMA 250- Enclosures for Electrical Equipment. Each type specifies characteristics of an enclosure, but not, for example, a specific enclosure size. Note that higher numbers do not include the lower-numbered tests. For example, types 3, 4 and 6 are intended for outdoor ...