enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. IEC 61508 - Wikipedia

    en.wikipedia.org/wiki/IEC_61508

    IEC 61508 is an international standard published by the International Electrotechnical Commission (IEC) consisting of methods on how to apply, design, deploy and maintain automatic protection systems called safety-related systems.

  3. ISO/IEC 31010 - Wikipedia

    en.wikipedia.org/wiki/ISO/IEC_31010

    risk assessment (risk identification, risk analysis, risk evaluation) risk treatment; monitoring and review "Risk assessment is the overall process of risk identification, risk analysis and risk evaluation" (ISO 31010) Risk can be assessed at any level of the company’s operations or goals.

  4. Electrical safety testing - Wikipedia

    en.wikipedia.org/wiki/Electrical_safety_testing

    MOPP safety standards aim to set basic safety requirements for medical electrical equipment. "With hazardous voltages present in a system a robust and reliable approach to isolation is needed such that multiple and un-related insulation system failures would need to occur before an operator or patient is put at risk.

  5. Safety engineering - Wikipedia

    en.wikipedia.org/wiki/Safety_engineering

    These techniques are just ways of finding problems and of making plans to cope with failures, as in probabilistic risk assessment. One of the earliest complete studies using this technique on a commercial nuclear plant was the WASH-1400 study, also known as the Reactor Safety Study or the Rasmussen Report.

  6. List of ISO standards 30000–99999 - Wikipedia

    en.wikipedia.org/wiki/List_of_ISO_standards_30000...

    ISO/TR 31004:2013 Risk management – Guidance for the implementation of ISO 31000; ISO/IEC 31010:2009 Risk management – Risk assessment techniques; ISO 31030:2021 Travel risk management — Guidance for organizations; ISO/IEC/IEEE 31320 Information technology – Modeling Languages. ISO/IEC/IEEE 31320-1:2012 Part 1: Syntax and Semantics for ...

  7. Safety integrity level - Wikipedia

    en.wikipedia.org/wiki/Safety_integrity_level

    Should the risk assessment establish that the required SIL cannot be achieved by a SIL4 SIF, then alternative arrangements must be designed, such as non-instrumented safeguards (e.g, a pressure relief valve). [1] There are several methods used to assign a SIL. These are normally used in combination, and may include: [1] Risk matrices; Risk graphs

  8. Electrical safety standards - Wikipedia

    en.wikipedia.org/wiki/Electrical_safety_standards

    Electrical shocks on humans can lead to permanent disabilities or death. Size, frequency and duration of the electrical current affect the damage. [8] The effects from electric shock can be: stopping the heart beating properly, preventing the person from breathing, causing muscle spasms. The skin features also affect the consequences of ...

  9. Failure modes, effects, and diagnostic analysis - Wikipedia

    en.wikipedia.org/wiki/Failure_Modes,_Effects...

    An additional column may be added to an FMEDA spreadsheet and probability of detection for each component failure mode is estimated. The cumulative effectiveness of the proof test is calculated in the same way as automatic diagnostic coverage. FMEDA tools can also calculate latent fault effectiveness.