Search results
Results from the WOW.Com Content Network
The treatment of boiler water can be put into two parts. These are internal treatment and external treatment. (Sendelbach, p. 131) [4] The internal treatment is for boiler feed water and external treatment is for make-up feed water and the condensate part of the system. Internal treatment protects against feed water hardness by preventing ...
With oxygenated treatment, oxygen is injected into the feedwater to keep the oxygen level between 30 and 50 ppb. OT programs are most commonly used in supercritical (i.e. >3250psi) power boilers. The ability to change an existing sub-critical boiler over to an OT program is very limited.
The boiler feedwater is sprayed into section where it is preheated by the rising steam from the sparger. The purpose of the feedwater spray nozzle and the preheat section is to heat the boiler feedwater to its saturation temperature to facilitate stripping out the dissolved gases in the following deaeration section. The preheated feedwater then ...
A means had to be provided, of course, to put the initial charge of water into the boiler (before steam power was available to operate the steam-powered feedwater pump). The pump was often a positive displacement pump that had steam valves and cylinders at one end and feedwater cylinders at the other end; no crankshaft was required.
Boiler water is liquid water within a boiler, or in associated piping, pumps and other equipment, that is intended for evaporation into steam.The term may also be applied to raw water intended for use in boilers, treated boiler feedwater, steam condensate being returned to a boiler, or boiler blowdown being removed from a boiler.
Pre-heat the feedwater; Provide a storage/surge volume; Based on the relevant theoretical Rankine cycle diagram, there are four main processes, or stages: Stages 1→2: Water pressure is raised from low to high by one or more pumps. Stages 2→3: Water is heated to boiling in either a conventional boiler or a nuclear propulsion steam generator
In order to justify installation of a dealkalizer on low-pressure boilers, the alkalinity content should be above 50 ppm with the amount of make-up water exceeding 1,000 gallons (approx. 4,000 litres) per day. Cooling system make-up will also benefit from reduced alkalinity.
Pages for logged out editors learn more. Contributions; Talk; Boiler feedwater treatment