A standard RTD sheath is 3.175 to 6.35 mm (0.1250 to 0.2500 in) in diameter; sheath diameters for thermocouples can be less than 1.6 mm (0.063 in). Accuracy and stability requirements If a tolerance of 2 °C is acceptable and the highest level of repeatability is not required, a thermocouple will serve.
Resistance temperature detector (RTD) Pyrometer; Langmuir probes (for electron temperature of a plasma) Infrared thermometer; Other thermometers; One must be careful when measuring temperature to ensure that the measuring instrument (thermometer, thermocouple, etc.) is really the same temperature as the material that is being measured.
Thermocouples can be connected in series as thermocouple pairs with a junction located on either side of a thermal resistance layer. The output from the thermocouple pair will be a voltage directly proportional to the temperature difference across the thermal resistance layer and also to the heat flux through the thermal resistance layer.
A PTC thermistor attached in series with each device can assure the current is divided reasonably evenly between the devices. In crystal oscillators for temperature compensation, medical equipment temperature control, and industrial automation, silicon PTC thermistors display a nearly linear positive temperature coefficient (0.7%/°C).
A thermocouple, also known as a "thermoelectrical thermometer", is an electrical device consisting of two dissimilar electrical conductors forming an electrical junction.A thermocouple produces a temperature-dependent voltage as a result of the Seebeck effect, and this voltage can be interpreted to measure temperature.
Sensor inputs can be accelerometer, thermocouple, thermistor, resistance thermometer, strain gauge or bridge, and LVDT or RVDT. Specialized inputs include encoder, counter or tachometer, timer or clock, relay or switch, and other specialized inputs. Outputs for signal conditioning equipment can be voltage, current, frequency, timer or counter ...
A thermocouple probe. Temperature probes are used to make contact measurements of surface temperatures. They employ a temperature sensor such as a thermistor, thermocouple, or RTD, to produce a voltage that varies with temperature. In the case of thermistor and RTD probes, the sensor must be electrically stimulated to produce a voltage, whereas ...
Electronic thermostats, instead, use a thermistor or other semiconductor sensor, processing temperature change as electronic signals, to control the heating or cooling equipment. Conventional thermostats are example of " bang-bang controllers " as the controlled system either operates at full capacity once the setpoint is reached, or keeps ...