  2. Standard RAID levels - Wikipedia

    en.wikipedia.org/wiki/Standard_RAID_levels

    Diagram of a RAID 1 setup. RAID 1 consists of an exact copy (or mirror) of a set of data on two or more disks; a classic RAID 1 mirrored pair contains two disks.This configuration offers no parity, striping, or spanning of disk space across multiple disks, since the data is mirrored on all disks belonging to the array, and the array can only be as big as the smallest member disk.

  3. RAID - Wikipedia

    en.wikipedia.org/wiki/RAID

    RAID 5 consists of block-level striping with distributed parity. Unlike RAID 4, parity information is distributed among the drives, requiring all drives but one to be present to operate. Upon failure of a single drive, subsequent reads can be calculated from the distributed parity such that no data is lost. RAID 5 requires at least three disks ...

  4. Non-standard RAID levels - Wikipedia

    en.wikipedia.org/wiki/Non-standard_RAID_levels

    Row diagonal parity is a scheme where one dedicated disk of parity is in a horizontal "row" like in RAID 4, but the other dedicated parity is calculated from blocks permuted ("diagonal") like in RAID 5 and 6. [1] Alternative terms for "row" and "diagonal" include "dedicated" and "distributed". [2]

  5. Nested RAID levels - Wikipedia

    en.wikipedia.org/wiki/Nested_RAID_levels

    The first number in the numeric designation denotes the lowest RAID level in the "stack", while the rightmost one denotes the highest layered RAID level; for example, RAID 50 layers the data striping of RAID 0 on top of the distributed parity of RAID 5. Nested RAID levels include RAID 01, RAID 10, RAID 100, RAID 50 and RAID 60, which all ...

  6. Parity drive - Wikipedia

    en.wikipedia.org/wiki/Parity_Drive

    A parity drive is a hard drive used in a RAID array to provide fault tolerance. For example, RAID 3 uses a parity drive to create a system that is both fault tolerant and, because of data striping, fast. [1] Basically, a single data bit is added to the end of a data block to ensure the number of bits in the message is either odd or even. [2]

  7. RAID levels - Wikipedia

    en.wikipedia.org/wiki/RAID_level

    RAID stands for redundant array of independent disks (or, formerly, redundant array of inexpensive disks). RAID levels may refer to: Standard RAID levels, all the RAID configurations defined in the Common RAID Disk Drive Format standard, which is maintained by the Storage Networking Industry Association

  8. Parity bit - Wikipedia

    en.wikipedia.org/wiki/Parity_bit

    In the case of a RAID 3 array of 12 drives, 11 drives participate in the XOR calculation shown above and yield a value that is then stored on the dedicated parity drive. Extensions and variations on the parity bit mechanism "double," "dual," or "diagonal" parity, are used in RAID-DP.

  9. Disk array controller - Wikipedia

    en.wikipedia.org/wiki/Disk_array_controller

    Those RAID systems made their way to the consumer market, for users wanting the fault-tolerance of RAID without investing in expensive SCSI drives. Fast consumer drives make it possible to build RAID systems at lower cost than with SCSI, but most ATA RAID controllers lack a dedicated buffer or high-performance XOR hardware for parity calculation.