enow.com Web Search

  1. Ads

    related to: xtratherm insulation u value calculator for celotex

Search results

  1. Results from the WOW.Com Content Network
  2. Celotex - Wikipedia

    en.wikipedia.org/wiki/Celotex

    Celotex Corporation logo in 1923. Celotex Corporation is a defunct American manufacturer of insulation and construction materials. [1] [2] It was the subject of a number of high-profile lawsuits over products containing asbestos in the 1980s, eventually declaring Chapter 11 bankruptcy in 1990. [3]

  3. Heat transfer coefficient - Wikipedia

    en.wikipedia.org/wiki/Heat_transfer_coefficient

    Architects and engineers call the resulting values either the U-Value or the R-Value of a construction assembly like a wall. Each type of value (R or U) are related as the inverse of each other such that R-Value = 1/U-Value and both are more fully understood through the concept of an overall heat transfer coefficient described in lower section ...

  4. Thermal transmittance - Wikipedia

    en.wikipedia.org/wiki/Thermal_transmittance

    Although the concept of U-value (or U-factor) is universal, U-values can be expressed in different units. In most countries, U-value is expressed in SI units, as watts per square metre-kelvin: W/(m 2 ⋅K) In the United States, U-value is expressed as British thermal units (Btu) per hour-square feet-degrees Fahrenheit: Btu/(h⋅ft 2 ⋅°F)

  5. Thermal conductivity and resistivity - Wikipedia

    en.wikipedia.org/wiki/Thermal_conductivity_and...

    The construction industry makes use of measures such as the R-value (resistance) and the U-value (transmittance or conductance). Although related to the thermal conductivity of a material used in an insulation product or assembly, R- and U-values are measured per unit area, and depend on the specified thickness of the product or assembly. [note 2]

  6. Building insulation - Wikipedia

    en.wikipedia.org/wiki/Building_insulation

    The effectiveness of bulk insulation is commonly evaluated by its R-value, of which there are two – metric (SI) (with unit K⋅W −1 ⋅m 2) and US customary (with unit °F⋅ft 2 ⋅h/BTU), the former being 0.176 times the latter numerically, or the reciprocal quantity the thermal conductivity or U-value W⋅K −1 ⋅m −2.

  7. LG ranges recalled after dozens of fires burn people ... - AOL

    www.aol.com/lg-ranges-recalled-dozens-fires...

    About 500,000 ranges sold nationwide are being recalled after dozens of fires burned property, people and pets, LG Electronics said Wednesday in a notice posted by the U.S. Consumer Product Safety ...

  8. Dynamic insulation - Wikipedia

    en.wikipedia.org/wiki/Dynamic_insulation

    Dynamic insulation works best with a good thickness of insulation so taking 200 mm of cellulose insulation (k = 0.04 W/m °C) the dynamic U value for an air flow of 0.31 mm/s is calculated using equation above to be 0.066 W/m 2 °C. If a lower dynamic U-value is required then a material with lower air permeability than fibreboard would need to ...

  9. Cooling load temperature difference calculation method

    en.wikipedia.org/wiki/Cooling_load_temperature...

    U = Overall heat transfer coefficient in Btu/(ft2-hr-deg F) A = Area in square feet T1 = outdoor temperature in degrees F T2 = indoor temperature in degrees F For heat gains due to people, equipment (hooded and unhooded), and lighting

  1. Ads

    related to: xtratherm insulation u value calculator for celotex