  2. Water hammer - Wikipedia

    en.wikipedia.org/wiki/Water_hammer

    To keep water hammer low, pipe-sizing charts for some applications recommend flow velocity at or below 1.5 m/s (4.9 ft/s). Fit slowly closing valves. Toilet fill valves are available in a quiet fill type that closes quietly. Non-slam check valves do not rely on fluid flow to close and will do so before the water flow reaches significant velocity.

  3. Check valve - Wikipedia

    en.wikipedia.org/wiki/Check_valve

    A check valve, non-return valve, reflux valve, retention valve, foot valve, or one-way valve is a valve that normally allows fluid (liquid or gas) to flow through it in only one direction. [ 1 ] Check valves are two-port valves, meaning they have two openings in the body, one for fluid to enter and the other for fluid to leave.

  4. Double check valve - Wikipedia

    en.wikipedia.org/wiki/Double_check_valve

    A double check valve or double check assembly (DCA) is a backflow prevention device designed to protect water supplies from contamination. [1] It is different from the two-way check valves (sometimes erroneously referred to as double check valves) used in air brake systems on heavy trucks which select from the highest pressure source. It ...

  5. Reduced pressure zone device - Wikipedia

    en.wikipedia.org/wiki/Reduced_pressure_zone_device

    A reduced pressure zone device (RPZD, RPZ, or RPZ valve) is a type of backflow prevention device used to protect water supplies from contamination. RPZDs may also be known as reduced pressure principle (RP), reduced pressure principle backflow prevention devices , [ 1 ] [ 2 ] reduced pressure zone assemblies (RPZA), [ 3 ] or reduced pressure ...

  6. Backflow prevention device - Wikipedia

    en.wikipedia.org/wiki/Backflow_prevention_device

    Backflow prevention device. The simplest, most reliable way to provide backflow prevention is to provide an air gap.An air gap is simply an open vertical space between any device that connects to a plumbing system (like a valve or faucet) and any place where contaminated water can collect or pool.

  7. Water metering - Wikipedia

    en.wikipedia.org/wiki/Water_metering

    At high flow rates, water is normally diverted primarily or completely to the high flow element. The high flow element is typically a turbine meter. When flow rates drop to where the high flow element cannot measure accurately, a check valve closes to divert water to a smaller element that can measure the lower flow rates accurately.

  8. Tesla valve - Wikipedia

    en.wikipedia.org/wiki/Tesla_valve

    A Tesla valve, called a valvular conduit by its inventor, is a fixed-geometry passive check valve. It allows a fluid to flow preferentially in one direction, without moving parts. The device is named after Nikola Tesla , who was awarded U.S. patent 1,329,559 in 1920 for its invention.

  9. Flow coefficient - Wikipedia

    en.wikipedia.org/wiki/Flow_coefficient

    A simplified version of the definition is: The k v factor of a valve indicates "The water flow in m 3 /h, at a pressure drop across the valve of 1 kgf/cm 2 when the valve is completely open. The complete definition also says that the flow medium must have a density of 1000 kg/m 3 and a kinematic viscosity of 10 −6 m 2 /s, e.g. water. [clarify]