Search results

  1. Results from the WOW.Com Content Network
  2. Physics of magnetic resonance imaging - Wikipedia

    en.wikipedia.org/wiki/Physics_of_magnetic...

    A field strength of 1.0–1.5 T is a good compromise between cost and performance for general medical use. However, for certain specialist uses (e.g., brain imaging) higher field strengths are desirable, with some hospitals now using 3.0 T scanners. FID signal from a badly shimmed sample has a complex envelope.

  3. Magnetic resonance imaging - Wikipedia

    en.wikipedia.org/wiki/Magnetic_resonance_imaging

    The field strength of the magnet is measured in teslas – and while the majority of systems operate at 1.5 T, commercial systems are available between 0.2 and 7 T. 3T MRI systems, also called 3 Tesla MRIs, have stronger magnets than 1.5 systems and are considered better for images of organs and soft tissue. [7]

  4. Susceptibility weighted imaging - Wikipedia

    en.wikipedia.org/.../Susceptibility_weighted_imaging

    Susceptibility weighted imaging (SWI), originally called BOLD venographic imaging, is an MRI sequence that is exquisitely sensitive to venous blood, hemorrhage and iron storage. SWI uses a fully flow compensated, long echo, gradient recalled echo (GRE) pulse sequence to acquire images.

  5. Real-time MRI - Wikipedia

    en.wikipedia.org/wiki/Real-time_MRI

    These scanners operate at relatively low magnetic field strengths, such as 0.35 T or 0.55 T. Many RT-MRI acquisition sequences, such as bSSFP, experience significant off-resonance effects. Off-resonance effects increase linearly with B0 field strength, so minimizing B0 also minimizes these effects that can lead to artifacts and image distortion ...

  6. Diffusion-weighted magnetic resonance imaging - Wikipedia

    en.wikipedia.org/wiki/Diffusion-weighted...

    To sensitize MRI images to diffusion, the magnetic field strength (B1) is varied linearly by a pulsed field gradient. Since precession is proportional to the magnet strength, the protons begin to precess at different rates, resulting in dispersion of the phase and signal loss.

  7. T2*-weighted imaging - Wikipedia

    en.wikipedia.org/wiki/T2*-weighted_imaging

    where γ represents gyromagnetic ratio, and ΔB 0 the difference in strength of the locally varying field. [3] [4] Unlike T 2, T 2 * is influenced by magnetic field gradient irregularities. The T 2 * relaxation time is always shorter than the T 2 relaxation time and is typically milliseconds for water samples in imaging magnets.

  8. Functional magnetic resonance imaging - Wikipedia

    en.wikipedia.org/wiki/Functional_magnetic...

    In general, fMRI studies acquire both many functional images with fMRI and a structural image with MRI. The structural image is usually of a higher resolution and depends on a different signal, the T1 magnetic field decay after excitation. To demarcate regions of interest in the functional image, one needs to align it with the structural one.

  9. Template:Table of MRI sequences - Wikipedia

    en.wikipedia.org/wiki/Template:Table_of_MRI...

    Functional MRI (fMRI) Blood-oxygen-level dependent imaging: BOLD: Changes in oxygen saturation-dependent magnetism of hemoglobin reflects tissue activity. [26] Localizing brain activity from performing an assigned task (e.g. talking, moving fingers) before surgery, also used in research of cognition. [27] Magnetic resonance angiography (MRA ...