At least one author takes a different approach in order to avoid a need for the expression freestream static pressure. Gracey has written "The static pressure is the atmospheric pressure at the flight level of the aircraft". [15] [16] Gracey then refers to the air pressure at any point close to the aircraft as the local static pressure.
A diffuser is "a device for reducing the velocity and increasing the static pressure of a fluid passing through a system”. [1] The fluid's static pressure rise as it passes through a duct is commonly referred to as pressure recovery. In contrast, a nozzle is used to increase the discharge velocity and lower the pressure of a fluid passing ...
The airtightness of a building is often expressed in terms of the leakage airflow rate through the building's envelope at a given reference pressure (usually 50 pascal) [10] divided by the: Heated building volume V. At 50·Pa, it is called the air change rate at 50 Pa and usually noted n 50 (units: h −1). [13] [14] Envelope area A E.
Rooftop HVAC unit with view of fresh-air intake vent Ventilation duct with outlet diffuser vent. These are installed throughout a building to move air in or out of rooms. In the middle is a damper to open and close the vent to allow more or less air to enter the space. The control circuit in a household HVAC installation.
Air enters at the eye of the rotor, makes a right-angle turn, and is forced through the blades of the rotor by centrifugal force into the scroll-shaped housing. The centrifugal force imparts static pressure to the air. The diverging shape of the scroll also converts a portion of the velocity pressure into static pressure. [citation needed]
In fluid dynamics, the pressure coefficient is a dimensionless number which describes the relative pressures throughout a flow field. The pressure coefficient is used in aerodynamics and hydrodynamics. Every point in a fluid flow field has its own unique pressure coefficient, C p.
∆p is the pressure difference across the ductwork envelope expressed in Pa; n is the airflow exponent (0.5 ≤ n ≤ 1) This law enables to assess the airflow rate at any pressure difference regardless the initial measurement. Threshold limits in ductwork airtightness classifications usually assume an airflow exponent of 0,65.
The fan maintains a constant static pressure in the discharge duct regardless of the position of the VAV box. Therefore, as the box closes, the fan slows down or restricts the amount of air going into the supply duct. As the box opens, the fan speeds up and allows more air flow into the duct, maintaining a constant static pressure. [11]