  2. Ventilation (architecture) - Wikipedia

    en.wikipedia.org/wiki/Ventilation_(architecture)

    For residential buildings, which mostly rely on infiltration for meeting their ventilation needs, a common ventilation rate measure is the air change rate (or air changes per hour): the hourly ventilation rate divided by the volume of the space (I or ACH; units of 1/h). During the winter, ACH may range from 0.50 to 0.41 in a tightly air-sealed ...

  3. Underfloor air distribution - Wikipedia

    en.wikipedia.org/wiki/Underfloor_air_distribution

    Underfloor air distribution (UFAD) is an air distribution strategy for providing ventilation and space conditioning in buildings as part of the design of a HVAC system. UFAD systems use an underfloor supply plenum located between the structural concrete slab and a raised floor system to supply conditioned air to supply outlets (usually floor ...

  4. Solar chimney - Wikipedia

    en.wikipedia.org/wiki/Solar_chimney

    A solar chimney – often referred to as a thermal chimney – is a way of improving the natural ventilation of buildings by using convection of air heated by passive solar energy. A simple description of a solar chimney is that of a vertical shaft utilizing solar energy to enhance the natural stack ventilation through a building.

  5. Trickle vent - Wikipedia

    en.wikipedia.org/wiki/Trickle_vent

    The US Standard ASHRAE 62.1-2007: Ventilation for Acceptable Indoor Air Quality, only requires 4% of net floor area to be operable. This creates the potential for increased energy consumption where natural ventilation is provided by operable windows where supplemental air conditioning is provided, in addition to generally poor control over ventilation rates during hot summer or cold winter ...

  6. Stack effect - Wikipedia

    en.wikipedia.org/wiki/Stack_effect

    [10] [11] The equations apply only to buildings where air is both inside and outside the buildings. For buildings with one or two floors, h is the height of the building. For multi-floor, high-rise buildings, h is the distance from the openings at the neutral pressure level (NPL) of the building to either the topmost openings or the lowest ...

  7. Double-skin facade - Wikipedia

    en.wikipedia.org/wiki/Double-skin_facade

    These struts create a walkway between both 'skins' for ventilation, solar shading and maintenance. The double-skin façade is a system of building consisting of two skins, or façades, placed in such a way that air flows in the intermediate cavity. The ventilation of the cavity can be natural, fan supported or mechanical.