enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Parts-per notation - Wikipedia

    en.wikipedia.org/wiki/Parts-per_notation

    The quantity "1 ppm" can be used for a mass fraction if a water-borne pollutant is present at one-millionth of a gram per gram of sample solution. When working with aqueous solutions, it is common to assume that the density of water is 1.00 g/mL. Therefore, it is common to equate 1 kilogram of water with 1 L of water.

  3. Orders of magnitude (molar concentration) - Wikipedia

    en.wikipedia.org/wiki/Orders_of_magnitude_(molar...

    hydronium and hydroxide ions in pure water at 25 °C (pK W = 13.99) [14] 10 −6: μM: 10 −5: 10 −4: 180–480 μM: normal range for uric acid in blood [10] 570 μM: inhaled carbon monoxide induces unconsciousness in 2–3 breaths and death in < 3 min (12 800 ppm) [15] 10 −3: mM 0.32–32 mM: normal range of hydronium ions in stomach acid ...

  4. Molar concentration - Wikipedia

    en.wikipedia.org/wiki/Molar_concentration

    To create the solution, 11.6 g NaCl is placed in a volumetric flask, dissolved in some water, then followed by the addition of more water until the total volume reaches 100 mL. The density of water is approximately 1000 g/L and its molar mass is 18.02 g/mol (or 1/18.02 = 0.055 mol/g). Therefore, the molar concentration of water is

  5. Useful conversions and formulas for air dispersion modeling

    en.wikipedia.org/wiki/Useful_conversions_and...

    If a gaseous emission sample is analyzed and found to contain water vapor and a pollutant concentration of say 40 ppmv, then 40 ppmv should be designated as the "wet basis" pollutant concentration. The following equation can be used to correct the measured "wet basis" concentration to a "dry basis" concentration: [3]

  6. Air pollutant concentrations - Wikipedia

    en.wikipedia.org/wiki/Air_pollutant_concentrations

    If a gaseous emission sample is analyzed and found to contain water vapor and a pollutant concentration of say 40 ppmv, then 40 ppmv should be designated as the "wet basis" pollutant concentration. The following equation can be used to correct the measured "wet basis" concentration to a "dry basis" concentration:

  7. Dilution (equation) - Wikipedia

    en.wikipedia.org/wiki/Dilution_(equation)

    For example, if there are 10 grams of salt (the solute) dissolved in 1 litre of water (the solvent), this solution has a certain salt concentration . If one adds 1 litre of water to this solution, the salt concentration is reduced. The diluted solution still contains 10 grams of salt (0.171 moles of NaCl).

  8. Equivalent concentration - Wikipedia

    en.wikipedia.org/wiki/Equivalent_concentration

    Normality is defined as the number of gram or mole equivalents of solute present in one liter of solution.The SI unit of normality is equivalents per liter (Eq/L). = where N is normality, m sol is the mass of solute in grams, EW sol is the equivalent weight of solute, and V soln is the volume of the entire solution in liters.

  9. Mass fraction (chemistry) - Wikipedia

    en.wikipedia.org/wiki/Mass_fraction_(chemistry)

    A solution with 1 g of solute dissolved in a final volume of 100 mL of solution would be labeled as "1%" or "1% m/v" (mass/volume). This is incorrect because the unit "%" can only be used for dimensionless quantities. Instead, the concentration should simply be given in units of g/mL.