  2. Fuse cutout - Wikipedia

    en.wikipedia.org/wiki/Fuse_cutout

    In electrical distribution, a fuse cutout or cut-out fuse (often referred to as a cutout) is a combination of a fuse and a switch, used in primary overhead feeder lines and taps to protect distribution transformers from current surges and overloads. An overcurrent caused by a fault in the transformer or customer circuit will cause the fuse to ...

  3. IEC 60269 - Wikipedia

    en.wikipedia.org/wiki/IEC_60269

    NH fuses of sizes 000 and 00, rated 63A and 125A NH fuses of sizes 1, 2 and 3, rated 250A, 400A and 630A NH fuses [ 3 ] have a square or oblong body and blade-style terminals. These fuses are larger and have higher ratings than the screw type fuses, exceeding 100 kA.

  4. Recloser - Wikipedia

    en.wikipedia.org/wiki/Recloser

    On a 3-phase circuit, a recloser is more beneficial than three separate fuse cutouts. For example, on a wye to delta conversion, when cutouts are used on the wye side and only 1 out of 3 of the cutout fuses open, some customers on the delta side have a low voltage condition, due to voltage transfer through the transformer windings. Low voltage ...

  5. Thermal cutoff - Wikipedia

    en.wikipedia.org/wiki/Thermal_cutoff

    An assortment of thermal fuses. A thermal cutoff is an electrical safety device (either a thermal fuse or thermal switch) that interrupts electric current when heated to a specific temperature. These devices may be for one-time use (a thermal fuse), or may be reset manually or automatically (a thermal switch).

  6. Reference designator - Wikipedia

    en.wikipedia.org/wiki/Reference_designator

    1A1A44J5 - Unit 1, Assembly 1, Sub-Assembly 44, Jack 5 (J5 is a connector on a box referenced as A44) 1A1A45J333 - Unit 1, Assembly 1, Sub-Assembly 45, Jack 333 (J333 is a connector on a box referenced as A45) A cable connecting these two might be: 1A1W35 - In the assembly A1 is a cable called W35. Connectors on this cable would be designated:

  7. DIN 43700 - Wikipedia

    en.wikipedia.org/wiki/DIN_43700

    DIN 43700, was the specification by the Deutsches Institut für Normung for nominal front- and cut-out dimensions of measurement and control instruments for panel mounting. It has now been superseded by DIN IEC 61554:2002-08.

  8. Fuse (electrical) - Wikipedia

    en.wikipedia.org/wiki/Fuse_(electrical)

    UL 248-1 sets the general requirements for fuses, while the latter parts are dedicated to specific fuses sizes (ex: 248-8 for Class J, 248-10 for Class L), or for categories of fuses with unique properties (ex: 248-13 for semiconductor fuses, 248-19 for photovoltaic fuses).

  9. Fusible link - Wikipedia

    en.wikipedia.org/wiki/Fusible_link

    An electrical fusible link is a type of electrical fuse that is constructed simply with a short piece of wire typically four American wire gauge (AWG) sizes smaller than the wire that is being protected. For example, an AWG 16 fusible link might be used to protect AWG 12 wiring.