enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Gran plot - Wikipedia

    en.wikipedia.org/wiki/Gran_plot

    To use potentiometric (e.m.f.) measurements in monitoring the + concentration in place of readings, one can trivially set [+] = and apply the same equations as above, where is the offset correction /, and is a slope correction / (1/59.2 pH units/mV at 25°C), such that replaces .

  3. pH - Wikipedia

    en.wikipedia.org/wiki/PH

    The pH range is commonly given as zero to 14, but a pH value can be less than 0 for very concentrated strong acids or greater than 14 for very concentrated strong bases. [2] The pH scale is traceable to a set of standard solutions whose pH is established by international agreement. [3]

  4. Titration curve - Wikipedia

    en.wikipedia.org/wiki/Titration_curve

    A typical titration curve of a diprotic acid, oxalic acid, titrated with a strong base, sodium hydroxide.Both equivalence points are visible. Titrations are often recorded on graphs called titration curves, which generally contain the volume of the titrant as the independent variable and the pH of the solution as the dependent variable (because it changes depending on the composition of the ...

  5. Acid–base titration - Wikipedia

    en.wikipedia.org/wiki/Acid–base_titration

    The pH after the equivalence point depends on the concentration of the conjugate base of the weak acid and the strong base of the titrant. However, the base of the titrant is stronger than the conjugate base of the acid. Therefore, the pH in this region is controlled by the strong base. As such the pH can be found using the following: [1]

  6. Calibration curve - Wikipedia

    en.wikipedia.org/wiki/Calibration_curve

    A calibration curve plot showing limit of detection (LOD), limit of quantification (LOQ), dynamic range, and limit of linearity (LOL).. In analytical chemistry, a calibration curve, also known as a standard curve, is a general method for determining the concentration of a substance in an unknown sample by comparing the unknown to a set of standard samples of known concentration. [1]

  7. Variable pathlength cell - Wikipedia

    en.wikipedia.org/wiki/Variable_pathlength_cell

    This shows that the absorbance values on the plot are offset by an equal amount and the slope of the two plots are equal. Thus, the concentration calculated from the two plots is equal. Other scalar components that contribute to the absorbance of a given sample like contaminants on the cuvette or a different cuvette material also are averaged ...

  8. pH meter - Wikipedia

    en.wikipedia.org/wiki/PH_meter

    Portable, or field pH meters, are handheld pH meters that are used to take the pH of a sample in a field or production site. [19] In-line or in situ pH meters, also called pH analyzers, are used to measure pH continuously in a process, and can stand-alone, or be connected to a higher level information system for process control. [20]

  9. Sample space - Wikipedia

    en.wikipedia.org/wiki/Sample_space

    A sample space is usually denoted using set notation, and the possible ordered outcomes, or sample points, [5] are listed as elements in the set. It is common to refer to a sample space by the labels S, Ω, or U (for "universal set"). The elements of a sample space may be numbers, words, letters, or symbols.