Search results
Results from the WOW.Com Content Network
An NTC is commonly used as a temperature sensor, or in series with a circuit as an inrush current limiter. With PTC thermistors, resistance increases as temperature rises; usually because of increased thermal lattice agitations, particularly those of impurities and imperfections. PTC thermistors are commonly installed in series with a circuit ...
The integrated circuit sensor may come in a variety of interfaces — analogue or digital; for digital, these could be Serial Peripheral Interface, SMBus/I 2 C or 1-Wire.. In OpenBSD, many of the I 2 C temperature sensors from the below list have been supported and are accessible through the generalised hardware sensors framework [3] since OpenBSD 3.9 (2006), [4] [5]: §6.1 which has also ...
The lower the coefficient, the greater a decrease in electrical resistance for a given temperature increase. NTC materials are used to create inrush current limiters (because they present higher initial resistance until the current limiter reaches quiescent temperature), temperature sensors and thermistors.
Resistance thermometers are constructed in a number of forms and offer greater stability, accuracy and repeatability in some cases than thermocouples. While thermocouples use the Seebeck effect to generate a voltage, resistance thermometers use electrical resistance and require a power source to operate.
Finding temperature from resistance and characteristics [ edit ] The equation model converts the resistance actually measured in a thermistor to its theoretical bulk temperature, with a closer approximation to actual temperature than simpler models, and valid over the entire working temperature range of the sensor.
The first sealed thermometer was constructed in 1654 by the Grand Duke of Tuscany, Ferdinand II. [1]: 19 The development of today's thermometers and temperature scales began in the early 18th century, when Daniel Gabriel Fahrenheit produced a mercury thermometer and scale, both developed by Ole Christensen Rømer.
Negative temperature coefficient (NTC) thermistors and fixed resistors are often used to limit inrush current. NTC thermistors can be used as inrush-current limiting devices in power supply circuits when added in series with the circuit being protected. They present a higher resistance initially, which prevents large currents from flowing at ...
A thermocouple, also known as a "thermoelectrical thermometer", is an electrical device consisting of two dissimilar electrical conductors forming an electrical junction.A thermocouple produces a temperature-dependent voltage as a result of the Seebeck effect, and this voltage can be interpreted to measure temperature.